DSpace Repository

Evaluation of corneal biomechanical properties after uneventful standard coaxial phacoemulsification surgery

Show simple item record

dc.contributor.author Cankaya, Cem
dc.contributor.author Ulas, Fatih
dc.contributor.author Doganay, Derya
dc.contributor.author Firat, Penpegul
dc.contributor.author Doganay, Selim
dc.date.accessioned 2022-02-22T06:36:50Z
dc.date.available 2022-02-22T06:36:50Z
dc.date.issued 2018
dc.identifier.citation Cankaya, C., Ulas, F., Doganay, D., Firat, P., & Doganay, S. (2021). Evaluation of corneal biomechanical properties after uneventful standard coaxial phacoemulsification surgery . Annals of Medical Research, en_US
dc.identifier.uri http://hdl.handle.net/11616/53736
dc.description.abstract Aim: This study was designed to investigate the alteration of intraocular pressure measurements and biomechanical properties of the cornea in patients who underwent uneventful standard coaxial phacoemulsification cataract surgery through 2.75 mm corneal main incision with intraocular lens implantation. Material and Methods: 15 eyes of 15 patients admitted to our clinic because of the cataract problems in the study. Corneal hysteresis (CH), corneal resistance factor (CRF) measurements, Goldmann correlated (IOPg), and corneal compensated intraocular pressure (IOPcc) values were recorded by ocular response analyzer (ORA) before and 1 day, 1 week and 1 month after surgery. Results: The mean age of the patients was 64.3 ± 8.06 years. Preoperative mean CH, CRF, IOPg and IOPcc values were 8.23±2.10, 9.33±2.27, 18.54±3.42 and 19.66±3.22, respectively. The mean CH, CRF, IOPg and IOPcc values were 5.50±2.07, 8.69±2.04, 22.29±3.37 and 23.83±3.32, respectively on the first day after the surgery. The mean CH, CRF, IOPg and IOPcc values were 5.25±1.83, 8.29±2.10, 18.86±2.72 and 20.20±3.37, respectively of the first week after the surgery. The mean CH, CRF, IOPg and IOPcc values were 7.88±1.99, 8.37±1.83, 15.81±2.60 and 16.41±2.80, respectively in the first month after the surgery. Conclusion: These results revealed that the biomechanical properties of the cornea may change during the first one month period after uneventful standard coaxial phacoemulsification surgery en_US
dc.language.iso eng en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.title Evaluation of corneal biomechanical properties after uneventful standard coaxial phacoemulsification surgery en_US
dc.type article en_US
dc.relation.journal Annals of Medical Research en_US
dc.contributor.department İnönü Üniversitesi en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record