DSpace@İnönü

Transfusion-transmitted virus DNA in serum, tear and aqueous humour of

Basit öğe kaydını göster

dc.contributor.author Emre, S
dc.contributor.author Otlu, B
dc.contributor.author Cankaya, C
dc.contributor.author Doganay, S
dc.contributor.author Durmaz, R
dc.date.accessioned 2022-03-28T11:43:38Z
dc.date.available 2022-03-28T11:43:38Z
dc.date.issued 2007
dc.identifier.uri http://hdl.handle.net/11616/58127
dc.description.abstract Purpose: Transfusion-transmitted virus (TTV) is a novel non-enveloped, single-stranded DNA virus with unclear pathogenesis throughout the world. Many studies were conducted to determine this virus in various body fluids and different primer sets have been tested for accurate diagnosis. This study aimed to collect data on the prevalence of TTV in serum, tear and aqueous humour of patients undergoing planned cataract surgery and to determine efficacy of three different polymerase chain reaction (PCR) techniques.
dc.description.abstract Methods: A total of 72 specimens (24 each of serum, tear and aqueous humour specimens) were collected from 24 patients (11 male and 13 female) having age-related cataract. The patients did not have any other ocular pathology. TTV DNA was investigated by three different PCR methods: a seminested PCR performed with Okamato's primers, a one-step PCR performed with degenerative Takashi's primers and a commercial real-time PCR system.
dc.description.abstract Results: TTV DNA was detected in 20 (83.3%) of the 24 serum specimens by the one-step PCR and real-time PCR system. However, seminested PCR yielded a positivity rate of 25%. TTV DNA positivities of the one-step PCR and the real-time PCR system were 33.3% and 66.6% of the 24 tear specimens, respectively. Seminested PCR did not yield positive result in these specimens. From aqueous humour specimens, TTV DNA was detected in 3 (12.5%) of the 24 specimens only by the real-time PCR. TTV DNA positivity of seminested PCR was significantly low in all specimens.
dc.description.abstract Conclusions: TTV DNA was detected in serum, tear and aqueous humour of patients undergoing cataract surgery, supporting the idea that this virus can be detected almost all of the body fluids but at different rates under various PCR conditions and primer sets. Using commercial real-time PCR significantly increased the TTV DNA positivity.
dc.source CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY
dc.title Transfusion-transmitted virus DNA in serum, tear and aqueous humour of
dc.title patients undergoing cataract operation


Bu öğenin dosyaları:

Dosyalar Boyut Biçim Göster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster