dc.contributor.author |
Bahsi, E |
|
dc.contributor.author |
Sagmak, S |
|
dc.contributor.author |
Dayi, B |
|
dc.contributor.author |
Cellik, O |
|
dc.contributor.author |
Akkus, Z |
|
dc.date.accessioned |
2022-09-21T07:50:19Z |
|
dc.date.available |
2022-09-21T07:50:19Z |
|
dc.date.issued |
2019 |
|
dc.identifier.uri |
http://hdl.handle.net/11616/61523 |
|
dc.description.abstract |
Background: The aim of this study was to evaluate six different glass ionomer cement (GIC)-based restorative materials through comparisons of microleakage and fluoride release. Materials and Methods: For microleakage, 30 teeth were randomly separated into 6 groups of 5: Group 1 (Dyract: compomer), Group 2 (Freedom: compomer), Group 3 (Equia: high-viscosity glass ionomer cements), Group 4 (Fuji IX: resin-modified glass ionomer cement), Group 5 (Ketac Molar: traditional glass ionomer cement [TGIC]) and Group 6 (Voco: TGIC). For fluoride release of six different GIC-based restorative materials, standard samples were prepared of 4 mm thickness and 7 mm diameter. A total of 60 samples were obtained as 10 samples from each group. The analyses were made using a Thermo Orion 720 A+ ionometer with the Orion fluoride electrode. At the end of 24 h, 72 h, 7 days, 14 days, and 30 days, the electrode was placed into the dish containing the sample, distilled water, and TISAB II; a reading was taken; and the value shown on the screen was recorded. Results: For microleakage, a statistically significant difference was determined between the groups in respect of the occlusal variable (P < 0.05), no statistically significant gingival variable (P 0.05). About fluoride release: According to the repeated measures variance analysis results, the difference between the groups, and between the time-group interaction and according to time, was found to be statistically significant (P < 0.05). Conclusions: In terms of microleakage, it was concluded that all materials could be used in clinical applications. The Equia high-viscosity glass ionomer cements (HVGIC) was determined to be the material with the highest fluoride release value. |
|
dc.description.abstract |
C1 [Bahsi, E.; Sagmak, S.] Dicle Univ, Dept Restorat Dent, Fac Dent, TR-21280 Diyarbakir, Turkey. |
|
dc.description.abstract |
[Dayi, B.] Dicle Univ, Dept Biostat, Fac Med, Diyarbakir, Turkey. |
|
dc.description.abstract |
[Cellik, O.] Inonu Univ, Dept Restorat Dent, Fac Dent, Malatya, Turkey. |
|
dc.description.abstract |
[Akkus, Z.] Adiyaman Univ, Dept Restorat Dent, Fac Dent, Adiyaman, Turkey. |
|
dc.source |
NIGERIAN JOURNAL OF CLINICAL PRACTICE |
|
dc.title |
The evaluation of microleakage and fluoride release of different types |
|
dc.title |
of glass ionomer cements |
|