DSpace@İnönü

Doppler waveforms and blood flow parameters of the superior and inferior mesenteric arteries in patients having behçet disease with and without gastrointestinal symptoms

Basit öğe kaydını göster

dc.contributor.author Sığırcı, Ahmet
dc.contributor.author Şenol, Mustafa
dc.contributor.author Aydın, Erdinç
dc.contributor.author Kutlu, Ramazan
dc.contributor.author Alkan, Alpay
dc.contributor.author Altınok, M. Tayfun
dc.contributor.author Yoloğlu, Saim
dc.contributor.author Baysal, Tamer
dc.contributor.author Saraç, Kaya
dc.date.accessioned 2017-06-23T13:35:11Z
dc.date.available 2017-06-23T13:35:11Z
dc.date.issued 2003
dc.identifier.citation Sığırcı, A. Şenol, M. Aydın, E. Kutlu, R. Alkan, A. Altınok, M. T. Yoloğlu, S. Baysal, T. Saraç, K. (2003). Doppler Waveforms and Blood Flow Parameters of the Superior and Inferior Mesenteric Arteries in Patients Having Behçet Disease With and Without Gastrointestinal Symptoms. J Ultrasound Med, (22), 449–457. tr_TR
dc.identifier.uri http://www.jultrasoundmed.org/cgi/content/abstract/22/5/449?maxtoshow=&hits=10&RESULTFORMAT=&author1=Sigirci+&andorexacttitle=and&andorexacttitleabs=and&andorexactfulltext=and&searchid=1&FIR
dc.identifier.uri http://hdl.handle.net/11616/7166
dc.description.abstract Objective. To evaluate hemodynamic changes in mesenteric arteries in patients with Behçet disease with and without gastrointestinal symptoms. Methods. Doppler sonography of mesenteric arteries was performed in 25 symptomatic and 15 asymptomatic patients having Behçet disease and in 25 healthy control subjects. The peak systolic, minimal, and mean velocities, resistive and pulsatility indexes, inner diameter, cross-sectional area, and blood flow volume of mesenteric arteries were evaluated. The results were compared between patient groups and controls. Results. The mesenteric artery flow was significantly greater in patients in the symptomatic group than in those in the asymptomatic group or in controls. In the superior mesenteric artery, mean velocity and mean blood flow volume (0.35 ± 0.18 m/s and 711 ± 404 mL/min, respectively; P < .0001) in the symptomatic group were significantly higher than in the asymptomatic group (0.16 ± 0.07 m/s and 305 ± 168 mL/min, respectively) or in controls (0.15 ± 0.07 m/s and 290 ± 123 mL/min, respectively). The mean peak systolic velocity (1.23 ± 0.47 m/s; P < .005) in the symptomatic group was significantly higher than in controls (0.93 ± 0.23 m/s). In the inferior mesenteric artery, mean velocity and mean blood flow volume (0.25 ± 0.10 m/s and 139 ± 79 mL/min) in the symptomatic group were significantly higher than in the asymptomatic group (0.16 ± 0.07 m/s; P < .006; and 78 ± 26 mL/min; P < .007) or in controls (0.17 ± 0.07 m/s; P < .003; 83 ± 48 mL/min; P < .004). Conclusions. In this study, symptomatic patients with gastrointestinal Behçet disease were associated with a significant increase in mesenteric artery flow that could be evaluated easily on spectral patterns of arteries during Doppler sonography. The Doppler sonographic findings also revealed that intestinal involvement in patients with Behçet disease without gastrointestinal symptoms is not significantly different from that of healthy controls. tr_TR
dc.language.iso eng tr_TR
dc.publisher J Ultrasound Med tr_TR
dc.rights info:eu-repo/semantics/openAccess tr_TR
dc.subject Behçet disease tr_TR
dc.subject Doppler sonography tr_TR
dc.subject Duplex sonography tr_TR
dc.subject Gastrointestinal system tr_TR
dc.subject Mesenteric arteries tr_TR
dc.title Doppler waveforms and blood flow parameters of the superior and inferior mesenteric arteries in patients having behçet disease with and without gastrointestinal symptoms tr_TR
dc.type article tr_TR
dc.relation.journal J Ultrasound Med tr_TR
dc.contributor.department İnönü Üniversitesi tr_TR
dc.contributor.authorID 7768 tr_TR
dc.identifier.volume 22 tr_TR
dc.identifier.startpage 449 tr_TR
dc.identifier.endpage 457 tr_TR


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster