DSpace@İnönü

Single pass lead VDD pacing system in children and adolescents

Basit öğe kaydını göster

dc.contributor.author Çeliker, Alpay
dc.contributor.author Karakurt, Cemşit
dc.contributor.author Karagöz, Tevfik
dc.date.accessioned 2017-08-24T07:26:25Z
dc.date.available 2017-08-24T07:26:25Z
dc.date.issued 2006
dc.identifier.citation Çeliker, A. Karakurt, C. Karagöz, T. (2006). Single pass lead VDD pacing system in children and adolescents. Acta Cardiologica. 61. tr_TR
dc.identifier.uri http://hdl.handle.net/11616/7709
dc.description.abstract The dual-chamber pacing systems allow for AV synchrony, but generally require the placement of two separate transvenous leads. Single-lead atrioventricular synchronous pacing system (VDD) using single-pass leads has been accepted as therapeutic alternative for atrioventricular block with normal sinus node function. The aim of this study is to evaluate clinical performance of single-pass lead VDD pacing systems in 24 consecutive patients in a ten-year period.The study group includes 17 (70.8%) male and 7 (28.8%) female patients.The mean age and mean weight during pacemaker implantation was 10.4 ± 3.8 years (4-17 years) and 30 ± 11 kg (13.5-55 kg), respectively.The patients have been followed for 7-84 months (median 42 months). The percentage of atrial sensing-ventricular pacing changed from 75 to 99.9% at the last control. During the follow-up period, pacing mode was changed to VVIR due to complete loss of AV synchrony in five patients (21%). Four of them had underlying cardiac disease. In these patients loss of AV synchrony might be related to cardiac enlargement/abnormal cardiac anatomy or small atrial dipoleventricular tip length. Despite the loss of AV synchrony in post surgical AV block or dilated cardiomyopathy, single-lead VDD pacing systems can be successfully used in children with complete AV block and normal sinus node function. Patients and lead selection should be taken into consideration for the maintenance of AV synchrony. tr_TR
dc.language.iso eng tr_TR
dc.publisher Acta Cardiologica tr_TR
dc.rights info:eu-repo/semantics/embargoedAccess tr_TR
dc.subject Single-lead VDD pacemaker tr_TR
dc.subject Loss of AV synchrony tr_TR
dc.title Single pass lead VDD pacing system in children and adolescents tr_TR
dc.type article tr_TR
dc.relation.journal Acta Cardiologica tr_TR
dc.contributor.department İnönü Üniversitesi tr_TR
dc.contributor.authorID 113274 tr_TR