DSpace@İnönü

Calculating colon transit time with radionuclide filled capsules in constipated patients a new method for colon transit study

Basit öğe kaydını göster

dc.contributor.author Kekilli, Ersoy
dc.contributor.author Işık, Burak
dc.date.accessioned 2017-12-08T11:19:02Z
dc.date.available 2017-12-08T11:19:02Z
dc.date.issued 2005
dc.identifier.citation Kekilli E, Yagmur C, Isik B, Aydin O. M. (2005). Calculating colon transit time with radionuclide filled capsules in constipated patients a new method for colon transit study. Abdom Imaging (2005) 30:593–597. tr_TR
dc.identifier.uri https://link.springer.com/content/pdf/10.1007/s00261-005-0305-9.pdf
dc.identifier.uri http://hdl.handle.net/11616/7875
dc.description Abdom Imaging (2005) 30:593–597. tr_TR
dc.description.abstract Background: Colon motility disorders require reliable methods for calculating segmental colonic transit time. This study evaluated bowel transit time by means of a safe, easy, cheap, nondigestive, and nondisintegrating radionuclide-filled capsule that provided accurate and clear images. Methods: Radionuclide-filled minicontainers (MCs) were prepared from infusion sets by an apparatus used for sealing blood bags or plasmapheresis sets. In vitro stability studies were performed by immersing 5% methylene blue dye-filled MCs in buffers of variable pH and enzymes simulating the conditions in the stomach and the small bowel. Colon transit scintigraphy was performed with MCs filled with iodine 131 (n = 5) and thallium 201 (n = 8) that were placed in a commercially available capsule. Results: By in vitro acid, base, and intestinal enzyme resistance tests, no methylene blue leakage was determined visually and by spectrophotometric analysis. Accurate and clear images were obtained for colon transit study in constipated patients. After excretion of MCs in the feces, abdominal, myocardial, thyroid, and urinary bladder region counts were found to show the same activity as the background. Radionuclide leakage from MCs was not determined in vivo by gamma camera. Conclusion: This is a suitable, safe, easy, and cheap method to provide accurate and clear images for colon transit study in constipated patients. tr_TR
dc.language.iso eng tr_TR
dc.publisher Abdominal Imaging tr_TR
dc.relation.isversionof 10.1007/s00261-005-0305-9 tr_TR
dc.rights info:eu-repo/semantics/openAccess tr_TR
dc.subject Colon transit tr_TR
dc.subject Constipation tr_TR
dc.subject Radionuclide tr_TR
dc.subject Scintigraphy tr_TR
dc.title Calculating colon transit time with radionuclide filled capsules in constipated patients a new method for colon transit study tr_TR
dc.type article tr_TR
dc.relation.journal Abdominal Imaging tr_TR
dc.contributor.department İnönü Üniversitesi tr_TR
dc.contributor.authorID 110105 tr_TR
dc.contributor.authorID 38728 tr_TR
dc.identifier.volume 30 tr_TR
dc.identifier.issue 0 tr_TR
dc.identifier.startpage 593 tr_TR
dc.identifier.endpage 597 tr_TR


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster