DSpace Repository

Detection of rotor fault in three-phase induction motor in case of

Show simple item record

dc.contributor.author Goktas, T
dc.contributor.author Arkan, M
dc.contributor.author Ozguven, OF
dc.date.accessioned 2022-10-13T11:46:00Z
dc.date.available 2022-10-13T11:46:00Z
dc.date.issued 2015
dc.identifier.uri http://hdl.handle.net/11616/79313
dc.description.abstract This paper proposes a method for the separation of broken rotor bar failure and low-frequency load fluctuation in line-fed three-phase induction motor. In practice, the presence of load fluctuation at has the same effect on a stator current of induction motor as a broken rotor bar fault. In such cases, the detection of broken rotor bar failure becomes difficult. To discern rotor fault and load oscillations, the analytical signal angular fluctuation (ASAF) method, which is a combination of Hilbert transform and the space vector angular fluctuation method, is used. The presented experimental results prove that low-frequency load oscillation and rotor fault can reliably be discriminated using the ASAF signal spectrum.
dc.description.abstract C1 [Goktas, Taner] Hitit Univ, Osmancik OD Vocat Sch Higher Educ, Corum, Turkey.
dc.description.abstract [Arkan, Muslum] Inonu Univ, Dept Elect & Elect Engn, Malatya, Turkey.
dc.description.abstract [Ozguven, Omer Faruk] Inonu Univ, Dept Biomed Engn, Malatya, Turkey.
dc.source ELECTRICAL ENGINEERING
dc.title Detection of rotor fault in three-phase induction motor in case of
dc.title low-frequency load oscillation


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record