DSpace Repository

Determination of the particle capture radius in magnetic filters with

Show simple item record

dc.contributor.author Abbasov, T
dc.contributor.author Altunbas, AS
dc.date.accessioned 2022-10-19T12:37:37Z
dc.date.available 2022-10-19T12:37:37Z
dc.date.issued 2002
dc.identifier.uri http://hdl.handle.net/11616/84497
dc.description.abstract The determination of the liquid velocity profile in packed bed pores is a well-known problem in the practical applications and the theory of filtration and separation processes. Because the pore sizes are very small, the measurement of the liquid velocity in these areas is very difficult or impossible. By using the modified Kuwabara-Happel cell model, the liquid velocity profile in the pores of packed bed consisting of solid spheres and cylindrical wires was determined. The variation of the liquid velocity with the packed bed porosity and pore geometry has been investigated. By using these results, the expressions for drag force affecting the small particles in the pores and particle capture radius in magnetic filter have been obtained. The effect of the variation of some parameters of filtration system on the particle capture radius has been investigated. Comparisons of the theoretical and experimental results were found to be in good agreement.
dc.description.abstract C1 Inonu Univ, Fac Engn, TR-44069 Malatya, Turkey.
dc.source SEPARATION SCIENCE AND TECHNOLOGY
dc.title Determination of the particle capture radius in magnetic filters with
dc.title velocity distribution profile in pores


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record