DSpace@İnönü

The effects of mobile phones on pacemaker functions

Basit öğe kaydını göster

dc.contributor.author Tandoğan, İzzet
dc.contributor.author Temizhan, Ahmet
dc.contributor.author Yetkin, Ertan
dc.contributor.author Güray, Yeşim
dc.contributor.author İleri, Mehmet
dc.contributor.author Duru, Erdal
dc.contributor.author Şaşmaz, Ali
dc.contributor.author Çehreli, Şengül
dc.contributor.author Köse, Kenan
dc.date.accessioned 2020-09-23T11:26:13Z
dc.date.available 2020-09-23T11:26:13Z
dc.date.issued 2002
dc.identifier.citation TANDOĞAN İ,TEMİZHAN A,YETKİN E,GÜRAY Y,İLERİ M,DURU E,ŞAŞMAZ A,ÇEHRELİ S,KÖSE K (2002). The effects of mobile phones on pacemaker functions. Türk Kardiyoloji Derneği Arşivi, 30(11), 699 - 709. en_US
dc.identifier.uri https://app.trdizin.gov.tr/publication/paper/detail/TVRrek56azU
dc.identifier.uri http://hdl.handle.net/11616/18122
dc.description Yıl: 2002Cilt: 30Sayı: 11ISSN: 1016-5169 / 1308-4488Sayfa Aralığı: 699 - 709Metin Dili:İngilizce en_US
dc.description.abstract Öz:Çeşitli sistemler tarafından oluşturulan elektromanyetik alanın kalp pili fonksiyonları üzerindeki olumsuz etkileri bilinmektedir. Bu çalışmanın amacı mobil telefonların kalp pili fonksiyonları üzerindeki etkilerini değerlendirmektir. Bu amaçla 679 kalıcı kalp pilli hasta üzerinde çalışıldı. Çalışma iki basamak halinde uygulandı. Kalp pili lead polaritesi birinci basamakta unipolar, ikinci basamakta bipolar olarak ayarlandı. Her iki basamakta kalp pili sensitivitesi önce nominal değerlerde iken, daha sonrada o kalp pili için minimal değere indirilerek test yapıldı. Kalp pili cebine göre simetrik olarak yerleştirilen iki farklı mobil telefon (power output 2W, GSM 900 MHz) ile 50 cm, 30 cm, 20 cm, 10 cm ve mobil telefon antenleri kalp pili cebi ile temas ettirilerek, mobil telefonların açılma, standby, çaldırma, konuşulma ve telefonların kapatılması aşamasında test yapıldı. Otuzyedi kalp pilli hastada etkilenme saptandı (%5.5). Lead polaritesinin unipolar olması durumunda etkilenme bipolar olmasına göre daha fazlaydı (Sırayla %4.12, %1.40, p<0.05). Sensitivitenin artırılması kalp pili etkilenme oranı üzerinde tek başına etkili değildi (p>0.05). Etkilenme açısından iki ve tek boşluklu kalp pilleri arasında fark yoktu (p>0.05). Bir DDD-R kalp pilinde ventriküler tetiklenme, 33 VVI(R) kalp pilinde asenkron moda geçiş ve 3 VVI kalp pilinde inhibisyon saptandı. Kalp pili yaşı ilerledikçe mobil telefondan etkilenme oranı artıyordu (p<0.05). Etkilenmelerin hepsi reversibl idi. Sonuç olarak mobil telefonlar belli şartlar altında kalp pili fonksiyonları üzerinde olumsuz etkilere neden olabilirler. Etkilenme durumu, kalp pili inhibisyonu hariç hastalarda önemli bir semptoma neden olmaz ve mobil telefonun uzaklaştırılmasıyla normale döner. en_US
dc.description.abstract Abstract:The negative effect of the electromagnetic field generated by different systems on the pacemaker functions is very well known. The aim of this study is to evaluate the effect of mobile phones on pacemaker functions. A total of 679 patients with permanent pacemakers enrolled in this study. The study was performed in two steps. Pacemaker lead polarity was unipolar in the first step and bipolar in the second step. Pacemaker sensitivity was first at nominal values, yet it was reduced to the minimal value for that pacemaker and then tested. Two mobile phones (power output 2W, GSM 900 MHz) were symmetrically located on either sides of the pacemaker pocket with the antenna being at distances of 50, 30, 20 and 10 cm and at close contact with the pocket. The tests were performed when both mobiles were opened, on stand-by, receiving a call, during the call and were closed. Thirty-seven patients with pacemakers were affected (5.5%). When the lead polarity was unipolar, the rate of being affected was higher when compared to the bipolar state (4.12% and 1.40%, respectively, p&lt;0.05). The increase in sensitivity was not an independent factor on the rate of being affected (p&gt;0.05). There was not any difference between the single and dual-chamber pacemakers in the rate of being affected. There was ventricular triggering in one DDD-R pacemaker, transition to asynchronous mode in 33 VVI(R) pacemakers and inhibition in 3 VVI pacemakers. The rate of being affected was increased as the pacemaker got age (p&lt;0.05). All of these episodes were reversible. In conclusion, mobile phones might have negative effects on pacemaker functions under certain conditions. This does not result in any symptoms other than the inhibition of pacemakers and returns to normal when the mobile phones are taken away en_US
dc.language.iso tur en_US
dc.publisher Türk Kardiyoloji Derneği Arşivi en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.title The effects of mobile phones on pacemaker functions en_US
dc.title.alternative Mobil telefonların kalp pili fonksiyonları üzerindeki etkileri en_US
dc.type article en_US
dc.relation.journal Türk Kardiyoloji Derneği Arşivi en_US
dc.contributor.department İnönü Üniversitesi en_US


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster