DSpace@İnönü

DÜŞÜK POLİMERİZASYON BÜZÜLMESİ GÖSTEREN MODERN KOMPOZİTLER İLE METAKRİLAT ESASLI REZİN KOMPOZİTİN KONVERSİYON ORANLARININ DEĞERLENDİRİLMESİ

Basit öğe kaydını göster

dc.contributor.author Barutcigil, Çağatay
dc.contributor.author Ahmetoğlu, Fuat
dc.contributor.author Turgut, Hacer
dc.contributor.author Dayı, Burak
dc.contributor.author Yalçın, Muhammet
dc.date.accessioned 2020-11-09T08:13:00Z
dc.date.available 2020-11-09T08:13:00Z
dc.date.issued 2014
dc.identifier.citation BARUTCİGİL Ç,AHMETOĞLU F,TURGUT H,DAYI B,YALÇIN M (2014). DÜŞÜK POLİMERİZASYON BÜZÜLMESİ GÖSTEREN MODERN KOMPOZİTLER İLE METAKRİLAT ESASLI REZİN KOMPOZİTİN KONVERSİYON ORANLARININ DEĞERLENDİRİLMESİ. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi, 24(1), 39 - 43. en_US
dc.identifier.uri https://app.trdizin.gov.tr/makale/TWpJeU1UY3lNZz09
dc.identifier.uri http://hdl.handle.net/11616/18660
dc.description.abstract Öz:Amaç: Bu in-vitro çalışmanın amacı üç farklı rezin kompozitin konversiyon oranlarının belirlenmesidir. Gereç ve Yöntem: Bu çalışmada üç farklı rezin kompozit değerlendirildi; bir geleneksel metakrilat esaslı kompozit (Premise, Kerr, Orange, CA, ABD), bir siloran esaslı kompozit (Filtek Silorane, 3M ESPE, St.Paul. MN, ABD) ve yeni bir düşük polimerizasyon özelliğine sahip kompozit (GC Kalore, GC Europe, Leuven, Belçika). Kompozit örneklerinin konversiyon oranlarının ölçümleri bir FTIR spektroskopi (Perkin Elmer Spectrum One, MA, ABD) ile yapıldı. Tüm kompozit rezin örnekleri için FTIR ölçümleri, örnekler polimerize edilmeden önce ve örnekler polimerize edildikten sonra gerçekleştirildi. Bulgular: Siloran esaslı kompozit Filtek Siloran (%58,60), istatistiksel olarak anlamlı bir şekilde Premise (%44,65) ve Kalore'den (%44,53) daha yüksek konversiyon oranı gösterdi. Sonuç: Rezin kompozitlerin konversiyon oranı monomer yapılarına bağlı olarak değişebilmektedir ve siloran esaslı kompozitler daha iyi polimerize olabilmektedir. en_US
dc.description.abstract Abstract:Purpose: The purpose of this in-vitro study was to determine the degree of conversion of three different composite materials. Material and Methods: In this study three composite materials were analyzed; a traditional methacylate-based composite (Premise, Kerr, Orange, CA, USA), a silorane-based composite (Filtek Silorane, 3M ESPE, St.Paul. MN, USA) and a novel low-shrinking composite (GC Kalore, GC Europe, Leuven, Belgium). Degree of conversion was measured on the composite with FTIR spectroscopy (Perkin Elmer Spectrum One, MA, USA). FTIR analyses were performed at the prepolymerization and post-polymerization stages of tested materials. Results: The silorane-based novel composite resin Filtek Silorane (58,60%) showed significantly higher conversion degree when compared to Premise (44,65%) and Kalore (44,53%). Conclusion: The conversion degree of resin composite might depend on monomer structure and siloranbased composite polymerized better than other tested composites. en_US
dc.language.iso tur en_US
dc.publisher Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.title DÜŞÜK POLİMERİZASYON BÜZÜLMESİ GÖSTEREN MODERN KOMPOZİTLER İLE METAKRİLAT ESASLI REZİN KOMPOZİTİN KONVERSİYON ORANLARININ DEĞERLENDİRİLMESİ en_US
dc.title.alternative DEGREE OF CONVERSION OF NOVEL LOW-SHRINKING COMPOSITES AND METHACRYLATE-BASED RESIN COMPOSITE en_US
dc.type article en_US
dc.relation.journal Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi en_US
dc.contributor.department İnönü Üniversitesi en_US


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster