Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Aslan, Duygu Demiroz" seçeneğine göre listele

Listeleniyor 1 - 3 / 3
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    Accuracy of non-invasive hemoglobin monitoring by pulseCO-oximeter during hepatectomy in living liver donors
    (2021) Çolak, Yusuf Ziya; Aslan, Duygu Demiroz
    Aim: To evaluate the accuracy and agreement of the measurements made with the Masimo Rad7 device in living donor hepatectomy (LDH). Materials and Methods: A total of 63 living liver donors (LLDs) with ASA I-II scores who scheduled for LDH were included in the study. The Masimo noninvasive measurement probe was inserted to measure SpHb (mg/dL), pleth variability index (PVI, %) and perfusion index (PI,%). Heart rate, mean artery pressure, SpO2 , body temperature, BIS, PVI, SpHb, and PI were recorded as basal, after anesthesia induction, post-intubation, post-intubation plus 5 min, 10 min, and plus 1, 2, 3, 4, 5, 6 and 7h. In addition blood samples were collected for laboratory hemoglobin (Hblab) before the surgery incision and after the surgical procedure, and the values were recorded simultaneously with the other values. Results: Fifty-five LLDs age between 18 and 55 years were assessed. The mean PI value increased in all measurements compared to baseline, and it was statistically significant at the 5th minute (p<0.05). This value prominently decreased after the 20th minute and dropped below the baseline value at the 7th hour. This decrease was statistically significant at the 2nd hour measurements (p<0.05). A significant correlation was observed between SpHb and LabHb before the surgical incision (r=0.694, p<0.001). Correlation decreased in after surgery measurement. In addition, there was a statistically significant difference between the before surgery and after surgery PI measurements (p<0.001). Conclusion: We think that in LDH procedures, surgical process leads to a decrease in PI and reduces the accuracy of SpHb measurement, and thus, intraoperative SpHb monitoring should be evaluated together with PI value.
  • Küçük Resim Yok
    Öğe
    Effects of Septoplasty on Tp-e Interval and Tp-e/QT Ratio in Patients With Nasal Septal Deviation
    (Lippincott Williams & Wilkins, 2020) Tasolar, Hakan; Karatas, Mehmet; Aslan, Duygu Demiroz
    Objectives: There are multiple nasal airway pathologies leading to upper airway obstruction, and one of the most common ones is nasal septum deviation (NSD). Our study aimed to evaluate the effect of nasal septal surgery in patients with NSD on ventricular arrhythmogenesis using the novel electrocardiographic parameters, Tp-e interval, and Tp-e/QT ratio. Methods: This retrospective cross-sectional study included 102 consecutive patients diagnosed with NSD. All participants completed a validated outcomes instrument (the NOSE scale), echocardiographic and electrocardiographic evaluation before and 3 months after septoplasty. The degree of nasal septal deviation was evaluated with the Dreher classification. Results: All of the electrocardiography parameters (except heart rate and QTmin) were significantly decreased with the septoplasty operation. Electrocardiographic parameters have significantly decreased especially in marked NSD patients. (Delta = difference between the preoperative and postoperative values) Delta NOSE was positively correlated both Delta cTp-e (r = 0.348, P < .001) and Delta cTp-e/QT values (r = 0.536, P < .001). Conclusion: Consequently, marked NSD was associated with increased risk of arrhythmogenesis, which were too much improved after septoplasty. So, treatment of especially marked NSD not only reduces otolaryngological complaints, but also leads to improvement of ventricular repolarization parameters.
  • Küçük Resim Yok
    Öğe
    Hepatektomi Ameliyatlarında Minimal Akım Anestezisi Uygulaması
    (2022) Çolak, Yusuf Ziya; Aslan, Duygu Demiroz
    Amaç: Düşük akım anestezisi (DAA) %75'e varan anestezik ajan (AA) tasarrufu sağlar ve solunan anestezik gazın dinamiklerini iyileştirir, mukosilier klirensi arttırır, vücut ısısını korur ve su kaybını azaltır. DAA son yıllarda anestezi uzmanları için yüksek taze gaz akımını (TGA) önlemek için tavsiye edilmiş olsa da, DAA ve minimal akım anestezisi (MAA) kullanımı çeşitli nedenlerden ötürü sınırlıdır. Bu çalışmanın temel amacı, DAA ve MAA uygulamasının güvenli olup olmadığını araştırmaktır. İkinci amaç, bu yöntemler kullanıldığında tüketilen AA miktarını belirlemektir. Gereç ve Yöntem: Prospektif, gözlemsel olarak iki grupta çalışmaya 40 hepatektomi olgusu dahil edildi. Bir ameliyat odası sadece bu çalışma için tahsis edildi. Oksijen ihtiyacı göz önünde bulundurularak (yaklaşık 3-3.5 mL/kg/dk) 20 olgu için 300 mL/dk (grupM); 20 olgu için 600 mL/dk TGA (grupD) uygulandı. Desflurane (Suprane©) inhalasyon anestezik ajanı olarak kullanıldı ve remifentanil infüzyonu ile analjezi elde edildi. Hastaların demografik, solunum, hemodinamik, doku perfüzyon parametreleri (SpO2 ve NIRS) ve AA tüketim verileri toplanarak karşılaştırıldı. Bulgular: Gruplar arasında demografik veriler, ameliyat süresi, hemodinamik, solunum ve doku perfüzyon parametreleri açısından anlamlı bir fark saptanmamıştır. Bu parametreler tüm hastalarda her ölçüm aralığında normal sınırlar içindeydi. %40 FiO2 elde etmek için GrupD vakalarında flowmetreden ortalama %61 O2 (min=%56, maks=%65), GrupM vakalarında flowmetreden ortalama %89 O2 (min %79, maks. %100) kullanılmıştır (p <0.001). Saatlik AA tüketimi GrupM’de (10.50 ± 3 mL/sa) GrupD’ye göre yaklaşık %34 daha düşüktü (14.10 ± 4 mL/sa). Sonuç: Hepatektomilerde güvenlik sınırlarından sapmadan 300 mL/dk TGA hızında MAA uyguladık ve AA maliyetlerini 600 mL/dk DAA uygulamasına göre yaklaşık %34 azalttık.

| İnönü Üniversitesi | Kütüphane | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


İnönü Üniversitesi, Battalgazi, Malatya, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim