Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Bankoglu, Merve" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    Influence of Pigments and Pigmenting Methods on Color Stability of Different Silicone Maxillofacial Elastomers After 1-Year Dark Storage
    (Lippincott Williams & Wilkins, 2013) Bankoglu, Merve; Oral, Ihsan; Gul, Esma Basak; Yilmaz, Handan
    Purpose: The purpose of this study was to measure spectrophotometrically the color changes of pigmented maxillofacial silicone elastomers with different pigments and pigmenting methods after storing 1 year in the dark environment. Methods: Three maxillofacial silicones, Cosmesil M511 (CosM511), Cosmesil M522 (CosM522), and Multisil-Epithetic (Mult-Epit), were selected for this study. A total of 240 specimens were fabricated; 80 of each of the 3 elastomers (n = 5) (18 mm in diameter and 2 mm in thickness) were prepared in 6 colorant categories (5 colorant and 1 with no colorant). Specimens were stored in a black box representing a condition of total darkness and placed in a dark environment at ambient room temperature (22 degrees C + 10 degrees C) and humidity (50% +/- 10%) for 1 year. A color spectrophotometer was used to measure the Delta E* values of the test specimens to determine the color changes. Results: The lowest color changes were observed in CosM511 in white color (Delta E* = 1.31) and in Mult-Epit in white color (Delta E* = 1.82) in extrinsic coloration group. The highest color changes were observed in yellow color in CosM511 (Delta E* = 21.61) and CosM522 (Delta E* = 23.78) in silicone pigmented intrinsic coloration method. In coloration methods, intrinsic silicone pigmented groups in all colors except brown in Mult-Epit had the highest Delta E* values. Conclusions: Significant color changes were observed in both pigmented and unpigmented specimens, which were stored in dark environment and not exposed to sunlight.

| İnönü Üniversitesi | Kütüphane | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


İnönü Üniversitesi, Battalgazi, Malatya, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim