Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Koşar F." seçeneğine göre listele

Listeleniyor 1 - 2 / 2
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    The clinical significance of QTc dispersion measurement for risk of syncope in patients with aortic stenosis
    (Futura Publishing Company Inc., 2001) Koşar F.; Tando?an I.; Hisar I.; Aytan Y.; Ileri M.
    Objectives: (1) To evaluate the clinical usefulness of QTc dispersion determination in aortic stenosis and (2) to compare the effects of QTc dispersion on the occurrence risk of syncope in aortic stenosis. Background: QT interval dispersion has long been known to be a marker of dispersion of ventricular repolarization and, hence, electrical instability. Additionally, it has been shown that these patients have a propensity to ventricular tachyarrhythmic syncope. Methods: The study included 86 patients with aortic stenosis who underwent left-heart catheterization and coronary angiography during investigation of syncope, as well as 30 control subjects. The patients were characterized with regards to the presence or absence of a history of syncope and the severity of aortic stenosis (the degree of peak transvalvular gradient). In addition, QT dispersion measurements were corrected for heart rate according to Bazett's formula and both were measured. Results: QTc dispersion was greater in patients with aortic stenosis than in the control subjects (60 ± 13 msec vs 38 ± 12 msec, P < 0.001). Similarly, QTc dispersion was greater in the patients with a history of syncope than in the patients with no history of syncope (68 ± 12 msec vs 53 ± 10 msec, P < 0.001). In addition, QTc dispersion values were greater in the patients with a high transvalvular gradient than in the patients with a low transvalvular gradient (65 ± 12 msec vs 50 ± 9 reset, P < 0.001). Multivariate logistic regression analysis showed that only an increased QTc dispersion had significant value for the risk of syncope in aortic stenosis. Conclusions: An increased QTc dispersion increases the occurrence risk for syncope in aortic stenosis. These results suggest that high values of QTc dispersion are a sensitive noninvasive marker for determining the risk for syncope in aortic stenosis.
  • Küçük Resim Yok
    Öğe
    Trace element status (Se, Zn, Cu) in heart failure
    (2006) Koşar F.; Şahin I.; Taşkapan Ç.; Küçükbay Z.; Güllü H.; Taşkapan H.; Çehreli Ş.
    Objective: It has been speculated that trace elements may play a role in the pathogenesis of heart failure. In the present study, we aimed to assess serum concentrations of selenium (Se), zinc (Zn) and copper (Cu) in patients with heart failure (HF) and to compare idiopathic dilated cardiomyopathy (IDCM) and ischemic cardiomyopathy (ICM) patients with healthy controls. Methods: This study population included 54 HF patients (26 IDCM patients and 28 ICM patients) and 30 healthy subjects. Serum levels of selenium, zinc, and copper were assessed by atomic absorption spectrophotometry method. Results: Serum concentrations of Se and Zn in HF patients were significantly lower than in healthy controls (p=0.000 and p<0.01, respectively). However, serum Cu concentrations in these patients were significantly higher than in controls (p=0.000). There were no significant difference in the trace elements status between IDCM and ICM patients (p>0.05 for all parameters). Relationships of the serum trace element concentrations studied with echocardiographic and hemodynamic parameters were not statistically significant. Conclusion: Our study showed that heart failure is associated with lower Se and Zn concentrations, and higher Cu concentration, and serum Se, Zn and Cu element profiles were similar in IDCM and ICM.

| İnönü Üniversitesi | Kütüphane | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.