Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Kurtcu, Busra" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    Evaluation of vestibulo-ocular reflex with functional head impulse test in healthy individuals: normative values
    (Frontiers Media Sa, 2023) Cengiz, Deniz Ugur; Erbek, Hatice Seyra; Colak, Sanem Can; Kurtcu, Busra; Demirel Birisik, Sumeyye; Karababa, Ercan; Kusman, Busra
    Objectives: This study aimed to determine the normative values of the functional head impulse test (fHIT) test in healthy young adults.Materials and methods: The study included 100 individuals, 58 females and 42 males, aged 20-25 years. Beon Solution Zero Branco (TV) fHIT test was applied to all participants. FHIT results were analyzed in terms of lateral-posterior-anterior semicircular canals (SSCs), gender, and right-left ear.Results: In the fHIT test, for the lateral SSC the mean percent correct answer (%CA) values for 4,000-6,000 degrees/s(2) and 1,000-7,000 degrees/s(2) were 88.52 +/- 9.04 and 89.91 +/- 6.95, respectively; for the posterior SSC, the mean %CA values for SSC 3000-6,000 degrees/s(2) and 1,000-7,000 degrees/s(2) were 90.63 +/- 8.69 and 91.16 +/- 7.42, respectively; for the anterior SSC, the mean %CA values for 3,000-6,000 degrees/s(2) and 1,000-7,000 degrees/s(2) were 91.21 +/- 7.96 and 91.49 +/- 7.13, respectively. There was no statistically significant difference between the right and left ear in %CA values at all accelerations in all SSCs (p > 0.05). There was a statistically significant difference between genders in the mean %CA values for 6,000-7,000 degrees/s(2), 4,000-6,000 degrees/s(2), and 1,000-7,000 degrees/s(2) in the lateral SSC and 3,000-6,000 degrees/s(2) in the anterior SSC (p < 0.05).Conclusion: The FHIT is a noninvasive test battery that functionally evaluates the VOR of the six semicircular canals. In clinical use, the determination of normative values at all accelerations (1,000-7,000 degrees/s(2)) constitutes an important database for future studies to distinguish pathologic results.

| İnönü Üniversitesi | Kütüphane | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


İnönü Üniversitesi, Battalgazi, Malatya, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim