Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Satiroglu, Nuray" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    Adsorption and on-line preconcentration of Cu(II), Cd(II) and Pb(II) ions from aqueous solution using procion red MX-3B immobilized poly(EGDMA-HEMA) microbeads
    (Parlar Scientific Publications (P S P), 2008) Buyuktuncel, Ebru; Satiroglu, Nuray; Denizli, Adil; Bektas, Sema
    The adsorption and preconcentration studies of Cu(II), Pb(II) and Cd(II) were investigated on Procion Red MX-3B attached poly(ethylene glycol dimethacrylate-hydroxyethyl methacrylate) [poly(EGDMA-HEMA)] microbeads. The effects of various experimental parameters were investigated using a batch and column technique. The adsorption data followed Langmuir, Freundlich and Dubinin-Radushkevich (D-R) isotherms, but the Langmuir model is better to represent the adsorption process. Procion Red MX-3B- poly(EGDMA-HEMA) microbeads were used as packing material for the minicolumn in an on-line preconcentration system for Cu(II), Pb(II) and Cd(II) determination. Metal ions were sorbed in the minicolumn, from which it could be eluted directly to the nebulizer-burner system of the flame atomic absorption spectrometer (FAAS). Elution of all metal ions from minicolumn can be made with 0.2 mol L-1 HNO3. For a preconcentration time of 2 min, the preconcentration factors were 51, 55 and 48, and the detection limits 1.25, 0.5 and 10 mu g L-1, for Cu(II), Cd(II) and Pb(II), respectively. When using 10 min preconcentration time for Pb(II), the preconcentration factor and detection limit were found to be 273 and 1.1 mu g L-1, respectively. The influence of diverse ions on the microbeads performance was also investioated. The accuracy of the method was tested by analyzing certified reference water (SPS-SW2- Surface Water and LGC 6010 - Hard Drinking Water) and spiked tap water samples. These results proved that the procedure can be applied satisfactorily for lead, copper and cadmium determination in water samples.

| İnönü Üniversitesi | Kütüphane | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


İnönü Üniversitesi, Battalgazi, Malatya, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim