Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Yakut, Kubra" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    Evaluation of the biomechanical effects and stability of titanium and carbon fiber-reinforced polyetheretherketone mini plates in Le Fort I advancement osteotomy fixation using finite element analysis
    (Elsevier, 2025) Yakut, Kubra; Ciftci, Sezai
    Aim: This study aimed to investigate the biomechanical properties of 60 % carbon fiber-reinforced polyetheretherketone (Cfr-PEEK), which exhibits high mechanical strength and can address the limitations of titanium mini plates used in Le Fort I osteotomy. Material and Method: Models were created using the FEA method based on tomography images of adult individuals. A 5 mm maxillary advancement was applied to the models following Le Fort I osteotomy. Mini plates made of titanium and 60 % Cfr-PEEK were used. Support was provided by the nasomaxillary and zygomaticomaxillary buttresses to fix a total of four l-shaped mini plates. Oblique loads of 125 N, directed from palatal to buccal, and a total of 250 N compression loads were applied to the central fossa of the premolar and molar teeth in the maxillary model at a 30 degrees angle relative to the long axis of the teeth. Displacement values at the osteotomy line, Von Mises stresses in the mini plate-screws, and principal stresses in the bone were compared. Results: Examination of stress values in the fixation systems of the models revealed higher stress values in the Cfr-PEEK model compared to the titanium model. However, these stresses did not reach levels that would deform the Cfr-PEEK fixation systems. Stress and displacement values in the bone were lower in the CfrPEEK model compared to the titanium model. Conclusion: According to the findings of our study, Cfr-PEEK represents a viable alternative to titanium for mini plate material in Le Fort I osteotomy, offering biomechanical advantages. (c) 2024 Elsevier Masson SAS. All rights are reserved, including those for text and data mining, AI training, and similar technologies.

| İnönü Üniversitesi | Kütüphane | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


İnönü Üniversitesi, Battalgazi, Malatya, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2026 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim