    Comparison of the sodium, potassium, chloride and glucose levels measured by a blood gas analyzer and an autoanalyzer
    (2020) Kaya, Omer; Yucel, Kamile
    Aim: A blood gas analyzers (BGA) are vital equipment frequently used in emergency departments and intensive care units. It is clinically important that the measurements of a BGA and an autoanalyzer (AA) provide equivalent results, which is confirmed by their proximitiy to the absolute value. This study aimed to compare the sodium (Na+), potassium (K+), chloride (Cl-) and glucose values in venous blood samples measured with a BGA and a standard AA with external quality control values.Material and Methods: The results of patients that presented to our emergency department between April 1, 2019 and July 1, 2019 and underwent the measurements of Na+ (n = 5,908), K+ (n = 5,755), Cl- (n = 5,101) and glucose (n = 5,871) simultaneously by BGA and AA were retrospectively compared. Results: In the Spearman correlation analysis between the two measurements, the correlation coefficient (r) was found as 0.78, 0.88, 0.89 and 0.97 for Na+, K+, Cl- and glucose, respectively. According to the Bland-Altman analysis, in the comparison of Na+, K+, Cl- and glucose values, the average bias percentages at the 95% confidence interval were -0.8 (4.8 to -6.4), -9 (8.6 to -26.5), -0.2 (6.2 to -6.5), and 0.3 (21.8 to -21.3), respectively. Conclusion: We concluded that the Na+ and Cl- results obtained from BGA can be used instead of those obtained from an AA; however, the blood gas K+ and glucose results of the former cannot replace those of the latter.

| İnönü Üniversitesi | Kütüphane | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


İnönü Üniversitesi, Battalgazi, Malatya, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim