Effects of different positive end expiratory pressure values on liver function and indocyanine green clearance test in liver transplantation donors a prospective randomized double blind study

dc.authorid110105en_US
dc.contributor.authorBıçakçıoğlu, Murat
dc.contributor.authorAydoğan, Mustafa Said
dc.contributor.authorŞayan, Hasan
dc.contributor.authorToprak, Hüseyin İlksen
dc.contributor.authorIşık, Burak
dc.contributor.authorYılmaz, Sezai
dc.contributor.authorYoloğlu, Saim
dc.date.accessioned2017-08-07T07:55:58Z
dc.date.available2017-08-07T07:55:58Z
dc.date.issued2015
dc.departmentİnönü Üniversitesien_US
dc.description.abstractIntroduction. The aim of this study was demonstrate the influence of different positive end-expiratory pressure (PEEP) values on blood flow of the liver by indocyanine green (ICG) clearance test in donor patients. Methods. ICG clearance tests were conducted concurrently using a noninvasive monitor that tracks the plasma disappearance rate of ICG (PDR-ICG%/min) and 15-minute retention rate after administration of ICG (ICG-R15%). This study was performed in 40 patients who underwent right hepatectomy. Results. The positive end-expiratory pressure (PEEP) was 0 cm H20 in the first (control) group (group K) and 10 mm Hg in the second study group (group P). ICG clearance test values before general anesthesia (T0), after induction of general anesthesia (T1), after transection (T2), 24 hours postoperative (T3), and 72 hours postoperative (T4) were recorded. Simultaneously, hemoglobin (Hgb), hematocrit (Hct), platelet count, plasma levels of prothrombin (PT), International Normalized Ratio (INR), total bilirubin, direct bilirubin, albumin, aspartate aminotransferase, and alanine aminotransferase values were analyzed. In terms of the plasma disappearance rate and retention rate of ICG 15 minutes after administration, significant difference was not observed between groups. PT and INR values were different within comparisons groups (P < .05). There were significant differences in Hgb and Hct values compared with the baseline values (T0) within group (T1, T2, T3, T4) measurements and between group comparisons at T0 and T4 (P < .05). Systemic arterial pressure, mean arterial pressure, and central venous pressure were significantly different between the groups (P < .05). Conclusions. Given the small magnitude and limited clinical significance of these changes, we conclude that PEEP values between 0 and 10 cm H2O have no effect on global liver function and liver-related liabilities tests in patients undergoing elective liver donor surgeryen_US
dc.identifier.citationBıçakçıoğlu, M. Aydoğan, M. S. Şayan, H. Toprak, H. İ. Işık, B. Yılmaz, S. Yoloğlu, S. (2015). Effects of different positive end expiratory pressure values on liver function and indocyanine green clearance test in liver transplantation donors a prospective randomized double blind study. Transplantation Proceedings. 47(4), 1190–1193.en_US
dc.identifier.doi10.1016/j.transproceed.2015.01.028en_US
dc.identifier.endpage1193en_US
dc.identifier.issn00411345
dc.identifier.issue4en_US
dc.identifier.startpage1190en_US
dc.identifier.urihttp://linkinghub.elsevier.com/retrieve/pii/S0041134515002316
dc.identifier.urihttps://hdl.handle.net/11616/7467
dc.identifier.volume47en_US
dc.language.isoenen_US
dc.publisherTransplantation Proceedingsen_US
dc.relation.ispartofTransplantation Proceedingsen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleEffects of different positive end expiratory pressure values on liver function and indocyanine green clearance test in liver transplantation donors a prospective randomized double blind studyen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Makale Dosyası.pdf
Boyut:
284.7 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale Dosyası
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.71 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: