DEFINING THE OPTIMUM PRESSURE FOR ACTIVE LEAKAGE CONTROL EFFICIENCY BY CONSIDERING ECONOMIC CRITERIA

dc.authoridFIRAT, MAHMUT/0000-0002-8010-9289
dc.authoridÖzdemir, Özgür/0000-0002-0573-9221
dc.authorwosidAtes, Abdullah/V-6929-2018
dc.authorwosidFIRAT, MAHMUT/ABG-7962-2020
dc.authorwosidÖzdemir, Özgür/JWO-3808-2024
dc.contributor.authorYilmaz, Salih
dc.contributor.authorFirat, Mahmut
dc.contributor.authorAtes, Abdullah
dc.contributor.authorOzdemir, Ozgur
dc.date.accessioned2024-08-04T20:57:35Z
dc.date.available2024-08-04T20:57:35Z
dc.date.issued2021
dc.departmentİnönü Üniversitesien_US
dc.description.abstractThe main purpose of this study is to determine the optimum pressure level by considering the economic criteria in case of applying pressure management and acoustic listening method, which are the most basic leakage reduction methods. For this purpose, optimum pressure levels were determined in the pilot regions selected and benefits to be obtained were discussed. The useful flow rate for ALC application in 4 regions was obtained as zero (0). In these DMAs, it was observed that the benefit to be obtained by applying only pressure management in these regions is more than the benefit that can be obtained from applying acoustic listening and pressure management together. Due to low water production costs, determining an active reduction strategy in the region will have uneconomic consequences for the Administration. Therefore, if there is no shortage of water resources, it would be a more ideal strategy to apply PM for DMA4. The results obtained from this study will constitute a reference within the scope of determining the optimum pressure level that will provide maximum benefit economically in the network when PM and ALC methods are used together.en_US
dc.description.sponsorshipInonu University, Scientific Research Project Funding [IUBAP FOA-2018-626, FDK-2020-2053]en_US
dc.description.sponsorshipThe authors thank Inonu University, Scientific Research Project Funding for their financial support (IUBAP FOA-2018-626; FDK-2020-2053).en_US
dc.identifier.endpage9153en_US
dc.identifier.issn1018-4619
dc.identifier.issn1610-2304
dc.identifier.issue7Aen_US
dc.identifier.startpage9142en_US
dc.identifier.urihttps://hdl.handle.net/11616/102756
dc.identifier.volume30en_US
dc.identifier.wosWOS:000678352300037en_US
dc.identifier.wosqualityQ4en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.language.isoenen_US
dc.publisherParlar Scientific Publications (P S P)en_US
dc.relation.ispartofFresenius Environmental Bulletinen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectWater distribution systemen_US
dc.subjectleakageen_US
dc.subjectactive leakage controlen_US
dc.subjectpressureen_US
dc.subjecteconomic analysisen_US
dc.titleDEFINING THE OPTIMUM PRESSURE FOR ACTIVE LEAKAGE CONTROL EFFICIENCY BY CONSIDERING ECONOMIC CRITERIAen_US
dc.typeArticleen_US

Dosyalar