Yazar "Muhammad, Fakhriy" seçeneğine göre listele
Listeleniyor 1 - 3 / 3
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Design of highly selective, and sensitive screen-printed electrochemical sensor for detection of uric acid with uricase immobilized polycaprolactone/polyethylene imine electrospun nanofiber(Pergamon-Elsevier Science Ltd, 2023) Muhammad, Fakhriy; Dik, Gamze; Kolak, Seda; Gedik, Kubra Karadas; Bakar, Busra; Ulu, Ahmet; Ates, BurhanUric acid (UA) plays a significant role in nerve center, human metabolism, and kidney system. Therefore, it is necessary to establish a simple, rapid, and sensitive detection method for UA. In recent years, researchers have been highly attracted by nanomaterials with satisfactory functions in electrochemical applications. In this study, polycaprolactone (PCL)/polyethylene imine (PEI) nanofiber membranes were prepared and used for the immobilization of uricase (UOx). The prepared membranes were characterized in terms of structure, composi-tion, and morphology. Afterward, the quantum dot screen printed electrode (QD SPCE) was modified with PCL/ PEI nanofiber membranes with and without methylene blue (MB) as an electron mediator. The electrochemical performance of the developed sensors was investigated by cyclic voltammetry (CV), differential pulse voltam-metry (DPV), and electrochemical impedance spectroscopy (EIS). Under the optimal conditions, the modified sensors provided a broad linear range (5.0-52.0 mu M) for the electrochemical detection of UA. Limit of detection (LoD) values were determined as 3.96 mu M and 1.85 mu M for the PCL/PEI/UOx/QD SPCE and PCL/PEI/UOx/MB/ QD SPCE, respectively. The four-week stability results showed the change in current for the PCL/PEI/UOx/QD SPCE and PCL/PEI/UOx/MB/QD SPCE to be 92% and 87%, respectively. Additionally, in the mixed interference test remaining current ratios for UA were 95% and 82% for the PCL/PEI/UOx/QD SPCE and PCL/PEI/UOx/MB/ QD SPCE, respectively. Most importantly, the effectiveness of the electrodes was also verified in real sample detection with satisfactory recovery (similar to 98-112%). Overall, the results showed that the PCL/PEI/UOx/QD SPCE and PCL/PEI/UOx/MB/QD SPCE have the advantages of simplicity, high sensitivity, and good selectivity for UA determination.Öğe Fabrication of electrospun polycaprolactone/chitosan nanofiber-modified screen-printed electrode for highly sensitive detection of diazinon in food analysis(Elsevier Sci Ltd, 2022) Topsoy, Oguz Kagan; Muhammad, Fakhriy; Kolak, Seda; Ulu, Ahmet; Gungor, Oznur; Simsek, Murat; Koytepe, SuleymanIn the present study, a screen-printed electrode for Diazinon (DZN) detection was modified with nanofibers prepared via electrospinning technique. The chemical structure, morphology, and crystallinity of the nanofibers were characterized in detail. The electrochemical behaviors of the modified screen-printed electrode were evaluated by cyclic voltammetry, differential pulse voltammetry, and electrochemical impedance spectroscopy. The spinning time, pH value and scan rates were optimized at 6 min, 5.25, and 50 mVs(-1), respectively. The limit of detection as 2.888 nM was obtained over a linear concentration range (3 nM-100 nM). Besides, DZN selectivity, repeatability, and storage stabilities of the developed sensor were proven. Meanwhile, the sensor was successfully applied for the determination of DZN in the tomato juice sample with recovery values in the range of 93.27-108.30%. The developed sensor could be a promising candidate to detect the presence and level of DZN in real samples.Öğe Uricase immobilization on nanofibre membranes prepared by electrospinning and its use as voltammetric uric acid biosensor(İnönü Üniversitesi, 2022) Muhammad, FakhriyÜrik asit klinikte gut ve hiperürisemi başta olmak üzere çeşitli hastalıkların belirteci olarak kullanılmaktadır. Bu nedenle serum ve gıda örnekleri gibi biyolojik numuneler hassas bir şekilde ölçümü oldukça önemlidir. Ürikaz (ürat oksidaz, E.C.1.7.3.3, UOx) vücutta ürik asidin allantoine oksidasyonundan sorumlu enzim olup özellikle in vitro ürik asit düzeyeni ölçmede yaygın kullanımı mevcuttur. Uygulamada ürik asit tayinine yönelik kolorimetrik, kromotografik, spektrofotometrik ve biyosensör temelli yöntemler mevcuttur. Bununla beraber özellikle hızlı sonuç veren, seçici ve kolay kullanılabilir sistemlerin oluşturulması ürik asit tayini için hala önemli bir ihtiyaçtır. Bu çalışmada ürik asidin seçici ve hassas bir şekilde belirlenmesi için elektroeğirme ile hazırlanan membranlar içeren perde baskılı elektrotların hazırlanması, ürikaz enziminin immobilizasyonu ve amperometrik ürik asit biyosensörü olarak kullanılması mevcuttur. Bu kapsamda elektroeğirme hazırlanan membranda mekanik mukavemeti nedeniyle polikaprolakton (PCL, % 10) ve enzimin immobilizasyonu için amin grubu içeren polietilenimin'den (PEI, % 7.5) faydalanılmıştır. İki farklı membran içeren Quantum Dot Screen Printed Electrode (QD - SPCE) hazırlanmıştır. Bunlardan biri PCL/PEI /UOx /QD – SPCE, diğeri ise metilen mavisi (MB) ile desteklenmiş PCL/PEI/UOx/MB/QD–SPCE şeklindedir. Hazırlanan membranlar yapısal olarak FTIR, EDX ve XRD, morfolojik açıdan SEM ve hidrofiliklik açıdan sıvı temas açısı ile karakterize edilmiştir. Voltametrik ölçümlerde standardizasyon, PBS pH 7.4'te 5 ve 52 µM arasında ürik asit (UA) konsantrasyonu için DPV (Diferansiyel Puls Voltametrisi) tekniği ile gerçekleştirilmiştir. Sonuçlar UOx/QD–SPCE için LOD:3,9619 ± 0,588 µM (R 2 = 0.9947) iken UOx/MB/QD–SPCE için LOD:1,8598 ± 0,2345 µM ( R 2 = 0.9988) olarak tespit edilmiştir. 4 haftalık stabilite sonuçları UOx/QD–SPCE ve UOx/MB/QD–SPCE için akımdaki değişimi sırasıyla %92 ve %87 olduğunu göstermiştir. Ayrıca interferansları içeren karışım çözeltisi kullanıldığında ürik asit için akım oranları UOx/QD–SPCE ve UOx/MB/QD–SPCE elektrolar için sırasıyla %95 ve %82 gerçekleşmiştir. Sonuç olarak hazırlanmış iki biyosensör sisteminde ürik asit ölçümünde literatürdeki sensörler ile karşılaştırılabilir düzeyde ölçüm niteliklerine sahip olduğu tespit edilmiştir.