Yazar "Timur, Suna" seçeneğine göre listele
Listeleniyor 1 - 2 / 2
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Conducting polymers with benzothiadiazole and benzoselenadiazole units for biosensor applications(Elsevier Science Sa, 2011) Emre, Fatma Bilge; Ekiz, Fulya; Balan, Abidin; Emre, Sinan; Timur, Suna; Toppare, LeventPoly(4,7-di(2,3)-dihydrothienol[3,4-b][1,4]dioxin-5-yl-benzo[1,2,5]thiadiazole) (PBDT) and poly(4,7-di(2,3)-dihydrothienol[3,4-b][1,4]dioxin-5-yl-2,1,3-benzoselenadiazole) (PESeE) were electrochemically deposited on graphite electrodes and used as immobilization matrices for biosensing studies. After electrochemical deposition of the polymeric matrices, glucose oxidase (GOx) was immobilized on the modified electrodes as the model enzyme. In the biosensing studies, the decrease in oxygen level as a result of enzymatic reaction was monitored at -0.7 V vs Ag/AgCl (3.0 M KCl) and correlated with substrate concentration. The biosensor was characterized in terms of several parameters such as operational and storage stabilities, kinetic parameters (K-m and I-max) and surface morphologies. The biosensor was tested on real human blood serum samples. (C) 2011 Elsevier B.V. All rights reserved.Öğe Functionalization of poly-SNS-anchored carboxylic acid with Lys and PAMAM: surface modifications for biomolecule immobilization/stabilization and bio-sensing applications(Royal Soc Chemistry, 2012) Demirci, Sema; Emre, Fatma Bilge; Ekiz, Fulya; Oguzkaya, Funda; Timur, Suna; Tanyeli, Cihangir; Toppare, LeventPoly(2-(2,5-di(thiophen-2-yl)-1H-pyrrol-1-yl) (SNS) acetic acid) was electrochemically deposited on graphite electrodes and functionalized with lysine (Lys) amino acid and poly(amidoamine) derivatives (PAMAM G2 and PAMAM G4) to investigate their matrix properties for biosensor applications. Glucose oxidase (GOx) was immobilized onto the modified surface as the model enzyme. X-Ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM) were used to report the surface properties of the matrices in each step of the biosensor construction. The biosensors were characterized in terms of their operational and storage stabilities and the kinetic parameters (K-m(app) and I-max). Three new glucose biosensors revealed good stability, featuring low detection limits (19.0 mu M, 3.47 mu M and 2.93 mu M for lysine-, PAMAM G2- and PAMAM G4-functionalized electrodes, respectively) and prolonged the shelf lives (4, 5, and 6 weeks for Lys-, PAMAM G2- and PAMAM G4-modified electrodes, respectively). The proposed biosensors were tested for glucose detection on real human blood serum samples.