Comparison of different arm positions and angles with ultrasound for infraclavicular block

dc.contributor.authorBinici, Orhan
dc.contributor.authorBuyukfirat, Evren
dc.date.accessioned2022-03-01T11:21:40Z
dc.date.available2022-03-01T11:21:40Z
dc.date.issued2019
dc.departmentİnönü Üniversitesien_US
dc.description.abstractAim: Nerve blocks are used more frequently with the introduction of ultrasound. Anesthesiologists prefer the infraclavicular nerve block because of its ease of administration and lack of complications. During the infraclavicular block, it is unclear to what angle the arm is to be given and in what position it is to be made. In our study, we aimed to measure and compare the distances of the axillary artery from the skin by giving different angles to the arm in the presence of ultrasound. Material and Methods: A total of 30 volunteers between the ages of 20-65 included in the study. While the forearm was in the anatomic position (Group A), the arm abducted from the shoulder at 0.45 and 90 degrees. At each angle, the distances of the different points of the axillary artery (posterior, anterior and central) to the skin compared. The same measurements repeated by flexing the forearm at 90 degrees from the elbow (Group B). Results: In Group A and Group B, the distances of all points of the axillary artery to the skin found to be inversely proportional to the abduction angle. In all measurements, the shortest skin distance found at 90 degrees of abduction angle (p< 0.05). There was no statistically significant difference between Group A and Group B in the same angles Conclusion: When performing ultrasound guided infraclavicular block, anesthesiologists should prefer the easiest method. We found that the distance of the axillary artery to the skin and needle entry decreased as the abduction angle of the arm increased in three different measurements. As a result of our study, we believe that the best angle for the infraclavicular block can be done by giving 90 degree abduction angle to the arm.en_US
dc.identifier.citationBinici, O., & Buyukfirat, E. (2021). Comparison of different arm positions and angles with ultrasound for infraclavicular block . Annals of Medical Research,en_US
dc.identifier.urihttps://hdl.handle.net/11616/54095
dc.language.isoenen_US
dc.relation.ispartofAnnals of Medical Researchen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleComparison of different arm positions and angles with ultrasound for infraclavicular blocken_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
976-979.pdf
Boyut:
637.74 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.71 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: