Changes in Anterior Chamber Parameters with the Pentacam Rotating Scheimpflug and Axial Length Measurements by Ultrasound in Patients Who Use Isotretinoin

dc.authorwosidSener, Serpil/ABI-6229-2020
dc.contributor.authorCumurcu, Tongabay
dc.contributor.authorSener, Serpil
dc.contributor.authorOzsoy, Ercan
dc.contributor.authorDoganay, Selim
dc.date.accessioned2024-08-04T20:35:51Z
dc.date.available2024-08-04T20:35:51Z
dc.date.issued2012
dc.departmentİnönü Üniversitesien_US
dc.description.abstractPurpose: Evaluation of changes in anterior chamber parameters with the Pentacam rotating Scheimpflug and axial length measurements (Alx) by ultrasound in patients who use isotretinoin for the treatment of acne vulgaris. Methods: Twenty-nine eyes of 29 patients (15 men, 14 women) were evaluated with the Pentacam before the treatment, and at the 3rd and 6th months of treatment. The axial length was evaluated by ultrasound biometry. The non-parametric paired t-test was used to compare pretreatment and 3rd and 6th month anterior chamber depth (ACD), anterior chamber volume (ACV), anterior chamber angle (ACA) width, central corneal thickness (CCT), lens thickness (LT), pupil size, axial length measurement (Alx) and mean keratometry values (K). Results: The mean age of the patients was 21.82 +/- 4.14 years. The differences between the pretreatment and 3rd and 6th month ACD, ACV, CCT, Alx, LT and mean K values were statistically significant (p < 0.05). The differences between the pretreatment and 3rd and 6th month pupil size measurements were not statistically significant (p > 0.05). The differences between the pretreatment and 3rd month ACA measurements were statistically significant (p > 0.05), but there was no statistically significant difference with 6th month values (p < 0.05). Conclusions: Isotretinoin treatment causes statistically significant changes in most anterior segment parameters during treatment.en_US
dc.identifier.doi10.3109/02713683.2011.635399
dc.identifier.endpage398en_US
dc.identifier.issn0271-3683
dc.identifier.issue5en_US
dc.identifier.pmid22510008en_US
dc.identifier.scopus2-s2.0-84859894491en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.startpage395en_US
dc.identifier.urihttps://doi.org/10.3109/02713683.2011.635399
dc.identifier.urihttps://hdl.handle.net/11616/95629
dc.identifier.volume37en_US
dc.identifier.wosWOS:000302914900007en_US
dc.identifier.wosqualityQ2en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherInforma Healthcareen_US
dc.relation.ispartofCurrent Eye Researchen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAnterior chamber parametersen_US
dc.subjectIsotretinoinen_US
dc.subjectPentacamen_US
dc.titleChanges in Anterior Chamber Parameters with the Pentacam Rotating Scheimpflug and Axial Length Measurements by Ultrasound in Patients Who Use Isotretinoinen_US
dc.typeArticleen_US

Dosyalar