Analysis of stator inter-turn short-circuit fault signatures for inverter-fed permanent magnet synchronous motors

Küçük Resim Yok

Tarih

2016

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

IEEE Computer Society

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

It is quite important to detect stator short-circuit fault, which is the most common fault type, at incipient stage. It is possible to carry out fault detection using Motor Current Signature Analysis (MCSA) method. In this study, stator current and voltage space vectors of PMSMs were analyzed with MCSA under various load torque, speed and fault percentages conditions. The Negative & positive harmonics were obtained by applying Fast Fourier Transform (FFT) to space vectors of stator current and voltage. It is suggested that by using the obtained fault signatures, stator inter-turn fault estimation can be achieved accurately. The results of comprehensive analysis carried out under various load torque and speed conditions show that characteristics fault signatures are both present in the current and the voltage space vectors spectra. © 2016 IEEE.

Açıklama

IEEE Industrial Electronics Society (IES);Institute of Electrical and Electronics Engineers (IEEE)
42nd Conference of the Industrial Electronics Society, IECON 2016 -- 24 October 2016 through 27 October 2016 -- 125546

Anahtar Kelimeler

Condition Monitoring, Fault Diagnosis, Inter-turn Short Circuit, PMSM, Positive and negative sequence harmonics

Kaynak

IECON Proceedings (Industrial Electronics Conference)

WoS Q Değeri

Scopus Q Değeri

N/A

Cilt

Sayı

Künye