A new method to separate broken rotor failures and low frequency load oscillations in three-phase induction motor

Küçük Resim Yok

Tarih

2013

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

IEEE Computer Society

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

For a time-varying loads, the presence of load fluctuation may sometimes have the same effect as broken rotor failure in a stator current of induction motors. In recent years, many methods, which are used to distinguish these two effects, have been published. In this study, a new method, which is based on Analytical Signal Angular Fluctuation (ASAF) signal, is developed to separate effects of load oscillation from broken rotor bar, especially when load oscillation is close to twice slip frequency. The simulation results are presented for the proposed method to show that, discerning broken rotor bar faults from low frequency load oscillation is possible. The developed method is independent of motor parameters. © 2013 IEEE.

Açıklama

'Generalitat Valenciana-Conselleria d'Educacio, Cultura i Esport';IEEE Power Electronics Society (PELS);SIEMENS;Universitat Politecnica de Valencia (UPV)
2013 9th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives, SDEMPED 2013 -- 27 August 2013 through 30 August 2013 -- Valencia -- 101470

Anahtar Kelimeler

broken rotor bar, fault detection, fault diagnosis, Hilbert transform, Induction motor, load torque oscillation

Kaynak

Proceedings - 2013 9th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives, SDEMPED 2013

WoS Q Değeri

Scopus Q Değeri

N/A

Cilt

Sayı

Künye