The preparation and sensor application of poly(p-aminophenol)
dc.authorid | EKİNCİ, ERGUN/0000-0001-9841-6642; | |
dc.authorwosid | EKİNCİ, ERGUN/ABG-4970-2020 | |
dc.authorwosid | /ABG-9766-2020 | |
dc.contributor.author | Ekinci, E | |
dc.contributor.author | Karagozler, AA | |
dc.contributor.author | Karagozler, AE | |
dc.date.accessioned | 2024-08-04T20:11:45Z | |
dc.date.available | 2024-08-04T20:11:45Z | |
dc.date.issued | 1996 | |
dc.department | İnönü Üniversitesi | en_US |
dc.description.abstract | An amperometric biosensor for glucose based on a novel polymeric matrix is described. The sensor was prepared by electrochemical polymerization of p-aminophenol in the presence of glucose oxidase on Pt substrates in a KCl solution at a potential of 0.6 V (vs. Ag/AgCl). The chronoamperometric response of poly(p-aminophenol)-glucose oxidase biosensor to hydrogen peroxide formed as the result of enzymatic reaction was measured at a potential of 0.7 V (vs. Ag/AgCl) in PBS solution. It was shown that a biosensor prepared by this onestep procedure has a linear range up to 6 mM glucose, a response time less than 5 s and a lifetime around 15 days. The sensitivity of the electrode was superior to that of much publicized polypyrrole based glucose oxidase electrode. Also, the substrate selectivity of PAP/GOx electrode was tested for coexisting substances such as lactose, sucrose, urea, paracetamol, uric and ascorbic acid and no discernible anodic response was observed above the background current. | en_US |
dc.identifier.doi | 10.1002/elan.1140080613 | |
dc.identifier.endpage | 574 | en_US |
dc.identifier.issn | 1040-0397 | |
dc.identifier.issue | 6 | en_US |
dc.identifier.scopus | 2-s2.0-0000830321 | en_US |
dc.identifier.scopusquality | N/A | en_US |
dc.identifier.startpage | 571 | en_US |
dc.identifier.uri | https://doi.org/10.1002/elan.1140080613 | |
dc.identifier.uri | https://hdl.handle.net/11616/92972 | |
dc.identifier.volume | 8 | en_US |
dc.identifier.wos | WOS:A1996UW69200012 | en_US |
dc.identifier.wosquality | N/A | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | Vch Publishers Inc | en_US |
dc.relation.ispartof | Electroanalysis | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | glucose | en_US |
dc.subject | glucose oxidase | en_US |
dc.subject | poly(p-aminophenol) | en_US |
dc.subject | enzyme electrode | en_US |
dc.subject | amperometric biosensor | en_US |
dc.title | The preparation and sensor application of poly(p-aminophenol) | en_US |
dc.type | Article | en_US |