Coil-Less Fluxgate Effect in Negatively Magnetostrictive Co72.5Si12.5B15 Amorphous Wire

dc.authoridBayri, Nevzat/0000-0001-7105-7707
dc.authoridKolat, Veli Serkan/0000-0002-8864-5051
dc.authorwosidBayri, Nevzat/ABG-9663-2020
dc.authorwosidIzgi, tekin/ABH-5655-2020
dc.authorwosidAtalay, Selcuk/AAA-5095-2021
dc.authorwosidAtalay, Funda/AAA-4130-2021
dc.authorwosidKolat, Veli Serkan/ABI-5280-2020
dc.contributor.authorAtalay, S.
dc.contributor.authorBayri, N.
dc.contributor.authorFidan, A.
dc.contributor.authorYagmur, V.
dc.contributor.authorIzgi, T.
dc.contributor.authorAtalay, F. E.
dc.contributor.authorKolat, V. S.
dc.date.accessioned2024-08-04T20:37:35Z
dc.date.available2024-08-04T20:37:35Z
dc.date.issued2013
dc.departmentİnönü Üniversitesien_US
dc.description.abstractIn this study, we have investigated coil-less fluxgate (CF) properties of as-cast and annealed Co72.5Si12.5.B15 amorphous wire. As-cast wire without any torsional strain shows nearly zero output in the second harmonic. When the as-cast wire is twisted a linear variation in the second harmonic of output was obtained as a function of applied magnetic field. It was also shown that a linear change in the output of the coil-less fluxgate sensor can be obtained using torsion annealed wire without twisting the wire during measurement. The second harmonic of U-wire showed a linear dependence at magnetic fields of +/- 400 A/m and the sensitivity of the sensor at 50 kHz frequency is about 75 V/T at 61 mA ac driving-current frequency for the wire annealed at 525 mA dc current for 20 minutes at 500 MPa tensile stress and 33 pi rad/m torsional strain.en_US
dc.description.sponsorshipTUBITAK [TBAG-109T361]en_US
dc.description.sponsorshipThis work was supported by TUBITAK under project number TBAG-109T361.en_US
dc.identifier.doi10.1166/sl.2013.2792
dc.identifier.endpage198en_US
dc.identifier.issn1546-198X
dc.identifier.issue1en_US
dc.identifier.scopus2-s2.0-84877991081en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.startpage195en_US
dc.identifier.urihttps://doi.org/10.1166/sl.2013.2792
dc.identifier.urihttps://hdl.handle.net/11616/96064
dc.identifier.volume11en_US
dc.identifier.wosWOS:000321593400049en_US
dc.identifier.wosqualityQ4en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherAmer Scientific Publishersen_US
dc.relation.ispartofSensor Lettersen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCoil-Less Fluxgateen_US
dc.subjectAmorphous Wireen_US
dc.subjectMagnetic Field Sensoren_US
dc.titleCoil-Less Fluxgate Effect in Negatively Magnetostrictive Co72.5Si12.5B15 Amorphous Wireen_US
dc.typeArticleen_US