Coil-Less Fluxgate Effect in Negatively Magnetostrictive Co72.5Si12.5B15 Amorphous Wire
dc.authorid | Bayri, Nevzat/0000-0001-7105-7707 | |
dc.authorid | Kolat, Veli Serkan/0000-0002-8864-5051 | |
dc.authorwosid | Bayri, Nevzat/ABG-9663-2020 | |
dc.authorwosid | Izgi, tekin/ABH-5655-2020 | |
dc.authorwosid | Atalay, Selcuk/AAA-5095-2021 | |
dc.authorwosid | Atalay, Funda/AAA-4130-2021 | |
dc.authorwosid | Kolat, Veli Serkan/ABI-5280-2020 | |
dc.contributor.author | Atalay, S. | |
dc.contributor.author | Bayri, N. | |
dc.contributor.author | Fidan, A. | |
dc.contributor.author | Yagmur, V. | |
dc.contributor.author | Izgi, T. | |
dc.contributor.author | Atalay, F. E. | |
dc.contributor.author | Kolat, V. S. | |
dc.date.accessioned | 2024-08-04T20:37:35Z | |
dc.date.available | 2024-08-04T20:37:35Z | |
dc.date.issued | 2013 | |
dc.department | İnönü Üniversitesi | en_US |
dc.description.abstract | In this study, we have investigated coil-less fluxgate (CF) properties of as-cast and annealed Co72.5Si12.5.B15 amorphous wire. As-cast wire without any torsional strain shows nearly zero output in the second harmonic. When the as-cast wire is twisted a linear variation in the second harmonic of output was obtained as a function of applied magnetic field. It was also shown that a linear change in the output of the coil-less fluxgate sensor can be obtained using torsion annealed wire without twisting the wire during measurement. The second harmonic of U-wire showed a linear dependence at magnetic fields of +/- 400 A/m and the sensitivity of the sensor at 50 kHz frequency is about 75 V/T at 61 mA ac driving-current frequency for the wire annealed at 525 mA dc current for 20 minutes at 500 MPa tensile stress and 33 pi rad/m torsional strain. | en_US |
dc.description.sponsorship | TUBITAK [TBAG-109T361] | en_US |
dc.description.sponsorship | This work was supported by TUBITAK under project number TBAG-109T361. | en_US |
dc.identifier.doi | 10.1166/sl.2013.2792 | |
dc.identifier.endpage | 198 | en_US |
dc.identifier.issn | 1546-198X | |
dc.identifier.issue | 1 | en_US |
dc.identifier.scopus | 2-s2.0-84877991081 | en_US |
dc.identifier.scopusquality | N/A | en_US |
dc.identifier.startpage | 195 | en_US |
dc.identifier.uri | https://doi.org/10.1166/sl.2013.2792 | |
dc.identifier.uri | https://hdl.handle.net/11616/96064 | |
dc.identifier.volume | 11 | en_US |
dc.identifier.wos | WOS:000321593400049 | en_US |
dc.identifier.wosquality | Q4 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | Amer Scientific Publishers | en_US |
dc.relation.ispartof | Sensor Letters | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Coil-Less Fluxgate | en_US |
dc.subject | Amorphous Wire | en_US |
dc.subject | Magnetic Field Sensor | en_US |
dc.title | Coil-Less Fluxgate Effect in Negatively Magnetostrictive Co72.5Si12.5B15 Amorphous Wire | en_US |
dc.type | Article | en_US |