DEVELOPMENT OF VOLTAMMETRIC MELANIN SENSOR WITH 2,5-DIMETHYLFURAN MODIFIED PLATINUM ELECTRODE

dc.contributor.authorBurc, Muammer
dc.contributor.authorAsma, Dilek
dc.contributor.authorDuran, Serap Titretir
dc.date.accessioned2024-08-04T20:51:38Z
dc.date.available2024-08-04T20:51:38Z
dc.date.issued2021
dc.departmentİnönü Üniversitesien_US
dc.description.abstractIn this study, an electrochemical sensor was developed for the electrochemical determination of melanin. For this purpose, phosphate buffer salt (PBS, pH 7.00) solution was used as an electrolyte, 2,5dimethylfuran (2,5-DMF) as a monomer, Pt wire as the auxilary electrode, Ag/AgCl electrode as the reference electrode and a platinum electrode as the working electrode. The modification of the electrode was performed by polymerization of 2,5-DMF at the bare Pt electrode surface using the cyclic voltammetry method. Parameters such as film thickness, scan rate and pulse amplitude with prepared 2,5-DMF modified platinum electrode (p(2,5-DMF)/PtE) were optimized by square wave voltammetry (SWV) in PBS buffer containing melanin. In optimum conditions, the anodic peak height showed a linear increase with the melanin concentration. The limit of detection (LOD) and limit of quantitation (LOQ) were calculated to be 0.088 mmol/l and 0.292 mmol/l, respectively, with melanin concentrations ranging from 0.10 to 2.20 mmol/l and the correlation coefficient (R2) was calculated as 0.9985. Stability of the prepared sensor was found to be 99.63% by using the reproducibility experiments (n = 15).en_US
dc.identifier.doi10.20450/mjcce.2021.2399
dc.identifier.endpage297en_US
dc.identifier.issn1857-5552
dc.identifier.issn1857-5625
dc.identifier.issue2en_US
dc.identifier.scopus2-s2.0-85124035502en_US
dc.identifier.scopusqualityQ4en_US
dc.identifier.startpage289en_US
dc.identifier.urihttps://doi.org/10.20450/mjcce.2021.2399
dc.identifier.urihttps://hdl.handle.net/11616/100459
dc.identifier.volume40en_US
dc.identifier.wosWOS:000747339100007en_US
dc.identifier.wosqualityQ4en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherSoc Chemists Technologists Madeconiaen_US
dc.relation.ispartofMacedonian Journal of Chemistry and Chemical Engineeringen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectsquare wave voltammetryen_US
dc.subjectmelaninen_US
dc.subjectsensoren_US
dc.subject2en_US
dc.subject5-dimethylfuranen_US
dc.titleDEVELOPMENT OF VOLTAMMETRIC MELANIN SENSOR WITH 2,5-DIMETHYLFURAN MODIFIED PLATINUM ELECTRODEen_US
dc.typeArticleen_US

Dosyalar