Evaluation of electrocardiographic parameters in amputee football players
dc.authorid | ALEXE, DAN IULIAN/0000-0002-6396-761X | |
dc.authorid | KURTOĞLU, Ahmet/0000-0002-9292-5419 | |
dc.authorid | Eken, Özgür/0000-0002-5488-3158 | |
dc.authorid | Sarbu, Ioan/0000-0002-8813-4112 | |
dc.authorid | Ciongradi, Carmen-Iulia/0000-0003-0673-0736 | |
dc.authorid | Sarbu, Ioan/0009-0004-5866-6347 | |
dc.authorwosid | ALEXE, DAN IULIAN/C-3791-2018 | |
dc.authorwosid | KURTOĞLU, Ahmet/AGC-7838-2022 | |
dc.authorwosid | Eken, Özgür/ABE-8274-2020 | |
dc.authorwosid | Candussi, Iuliana Laura/KHW-5505-2024 | |
dc.authorwosid | Sarbu, Ioan/N-3980-2018 | |
dc.authorwosid | Ciongradi, Carmen-Iulia/IIH-0030-2023 | |
dc.contributor.author | Kurtoglu, Ahmet | |
dc.contributor.author | Kurtoglu, Ertugrul | |
dc.contributor.author | Akguemues, Alkame | |
dc.contributor.author | Car, Bekir | |
dc.contributor.author | Eken, Oezguer | |
dc.contributor.author | Sarbu, Ioan | |
dc.contributor.author | Ciongradi, Carmen Iulia | |
dc.date.accessioned | 2024-08-04T20:54:37Z | |
dc.date.available | 2024-08-04T20:54:37Z | |
dc.date.issued | 2023 | |
dc.department | İnönü Üniversitesi | en_US |
dc.description.abstract | ObjectiveThe present study aimed to compare electrocardiographic (ECG) parameters of amputee football players (AF) with football players without disability (FP) and sedentary individuals without disability (SI). MethodsA total of 32 participants (AF = 9, FP = 11, SI = 12) were included in the study. ECG parameters including P-wave amplitude, P-wave duration, PR interval, QRS duration, RR interval, QT interval, corrected-QT interval (QTc), ST segment duration, Tp-e duration, Tp-e/QT and Tp-e/QTc ratios were assessed in all the study participants by using a 12-lead ECG device. OneWay ANOVA Test was used for statistical analysis. ResultsOf all ECG parameters, P-wave amplitude and QTc were significantly higher in the AF group in comparison to FP and SI groups. QRS duration was found to be lower in the AF group when compared to FP and SI groups. Myocardial repolarization parameters including Tp-e duration, Tp-e/QT and Tp-e/QTc ratios were similar between groups, as were other parameters such as P-wave duration, PR interval, RR interval, QRS duration and QT interval. ConclusionIt was found that some ECG parameters of amputee football players differ from those with non-disabled players and non-disabled sedentary individuals. These different parameters were within normal limits. | en_US |
dc.identifier.doi | 10.3389/fpsyg.2023.1189712 | |
dc.identifier.issn | 1664-1078 | |
dc.identifier.pmid | 37554132 | en_US |
dc.identifier.scopus | 2-s2.0-85167367445 | en_US |
dc.identifier.scopusquality | Q2 | en_US |
dc.identifier.uri | https://doi.org/10.3389/fpsyg.2023.1189712 | |
dc.identifier.uri | https://hdl.handle.net/11616/101506 | |
dc.identifier.volume | 14 | en_US |
dc.identifier.wos | WOS:001042243700001 | en_US |
dc.identifier.wosquality | Q2 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.indekslendigikaynak | PubMed | en_US |
dc.language.iso | en | en_US |
dc.publisher | Frontiers Media Sa | en_US |
dc.relation.ispartof | Frontiers in Psychology | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | amputation | en_US |
dc.subject | cardiac function | en_US |
dc.subject | disability | en_US |
dc.subject | electrocardiography | en_US |
dc.subject | football | en_US |
dc.title | Evaluation of electrocardiographic parameters in amputee football players | en_US |
dc.type | Article | en_US |