Color Stability of Provisional Restorative Materials in Different Mouthwash Solutions

dc.authoriddemirci, fatih/0000-0002-8744-5592
dc.authoridBakir, Metin/0000-0002-7788-9990
dc.authorwosiddemirci, fatih/ABG-8682-2020
dc.authorwosidDEGER, YALÇIN/HNC-2377-2023
dc.contributor.authorDeger, Yalcin
dc.contributor.authorBakir, Metin
dc.contributor.authorDemirci, Fatih
dc.contributor.authorDeveci, Buesra
dc.date.accessioned2024-08-04T20:53:06Z
dc.date.available2024-08-04T20:53:06Z
dc.date.issued2022
dc.departmentİnönü Üniversitesien_US
dc.description.abstractPurpose. This study is a comparison of the effects of temporary restorative materials (PRMs) on the color change that occurs due to the use of different mouthwash solutions in two time periods. Material and Methods. One hundred fifty disc-shaped specimens(10 mmx2 mm) were fabricated with three PRMs chemically polymerized PMMA (Imident-I), chemically polymerized bisacrylic composite resin (Acry temp-A), and CAD/CAM PMMA-based polymer (Telio CAD-T) according to manufacturers' instruction and using a CAD/CAM milling system (n=10). CIE L*a*b* values of specimens were recorded before immersion. Samples were immersed in solutions (Distilled water-DW, Kloroben-CHX, Listerine Advanced White-LAW, Listerine Total Care-TC, and Listerine Zero-TCZ) in two time periods (t(1),t(2)). Color measurements of the samples were made with the help of a spectro-photometer before and after they were removed in mouthwashes (VITA Easy shade V).Results. According to the statistical analysis results, significant differences were observed between the results obtained in our study. The highest roughness values in Delta E1 were seen in A-LAW (1.83) and the lowest in T-DW (0.61). In Delta E2, the highest roughness values were observed in I-LAW (2.70), and the lowest in T-DW (1.05). Delta E values of all obtained groups were found within clinically acceptable limits (Delta E < 3.7).Conclusions.The content of temporary restorative materials, the production technique, the type of mouthwash, and the immersion time of the restoration affect the color stability. Mouthwash with a whitening effect caused the most discoloration. Among the temporary restorative materials, it was the CAD/CAM material that best preserved its color stability.en_US
dc.identifier.doi10.1155/2022/9130117
dc.identifier.issn1687-8434
dc.identifier.issn1687-8442
dc.identifier.scopus2-s2.0-85141094632en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.urihttps://doi.org/10.1155/2022/9130117
dc.identifier.urihttps://hdl.handle.net/11616/100972
dc.identifier.volume2022en_US
dc.identifier.wosWOS:000877894300003en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherHindawi Ltden_US
dc.relation.ispartofAdvances in Materials Science and Engineeringen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectStaining Solutionsen_US
dc.subjectResin Compositesen_US
dc.subjectFluorideen_US
dc.subjectCad/Camen_US
dc.subjectDiscolorationen_US
dc.subjectMicrohardnessen_US
dc.subjectMouthrinsesen_US
dc.subjectImmersionen_US
dc.subjectCrownen_US
dc.titleColor Stability of Provisional Restorative Materials in Different Mouthwash Solutionsen_US
dc.typeArticleen_US

Dosyalar