Influence of Ferromagnetic Ribbon Width on Q Factor and Magnetoelastic Resonance Frequency

Küçük Resim Yok

Tarih

2021

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Polish Acad Sciences Inst Physics

Erişim Hakkı

info:eu-repo/semantics/openAccess

Özet

In this study, Fe40Ni38Mo4B18 (2826MB) amorphous ferromagnetic ribbons were used as a magnetoelastic sensor. The variation in resonance frequency and quality (Q) factor values of samples with a 30 mm length and different widths is investigated as a function of a magnetic field. It is observed that as the sample width increases, the change in resonance frequency and the Q factor both decrease. The parameter Q x amplitude/M is defined to understand the effect of a ribbon width on the resonance curve. According to this parameter, samples with 1 and 2 mm widths are found to have a better magnetoelastic effect.

Açıklama

Anahtar Kelimeler

Fluid-Flow Velocity, Wireless, Sensors, Temperature

Kaynak

Acta Physica Polonica A

WoS Q Değeri

Q4

Scopus Q Değeri

Q4

Cilt

139

Sayı

2

Künye