Comparison of a novel 3-dimensional-printed attachment transfer method with conventional methods in clear aligner therapy: An in vitro study
Küçük Resim Yok
Tarih
2026
Yazarlar
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Mosby-Elsevier
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
Introduction: This study aimed to compare the accuracy of a novel 3-dimensional (3D)-printed attachment transfer technique with conventional composite-based methods, evaluating the effect of template and thickness. Methods: Three transfer methods were investigated: nonflowable composite resin, flowable composite resin, and 3D-printed attachments with a transfer carrier. In the conventional attachment method, 4 different thermoplastic template sheet thicknesses were used: 0.3, 0.5, 0.75, and 0.8 mm. dardized reference model with 6 digitally planned attachments was used for all groups. Using each method, tachments were transferred to 3D-printed dental models, which were then scanned and superimposed reference model. Root mean square and mean distance values were calculated using CloudCompare software (version 2.14; www.danielgm.net/cc/) for surface deviation analysis. Results: Statistically significant ences were observed among the attachment transfer methods (P <0.001, Kruskal-Wallis test). The printed attachment group exhibited the highest geometric accuracy across all evaluated sites. Pairwise comparisons showed that the 3D-printed group performed significantly better than both composite groups (P <0.001, Dunn's test). Composite viscosity showed no significant effect on transfer accuracy, except for attachments 16 and 23 in mean distance values (P = 0.023-0.031) and attachment 16 mean square values (P = 0.043). Template thickness significantly influenced transfer accuracy, with aligners generally producing lower deviation values, particularly between Tristar (0.3 mm) and Track mm) (P <0.05 to P <0.001). Conclusions: The 3D-printed attachment transfer method demonstrated superior accuracy than conventional composite-based methods. Although the thinnest template exhibited deviations, accuracy varied among the different templates, suggesting that both material thickness composition may influence transfer performance. Composite viscosity did not substantially affect accuracy, as both flowable and nonflowable composite resins produced comparable results in attachment sites.
Açıklama
Anahtar Kelimeler
Orthodontic Tooth Movement, Efficacy, Design
Kaynak
American Journal of Orthodontics and Dentofacial Orthopedics
WoS Q Değeri
Q1
Scopus Q Değeri
Q1
Cilt
169
Sayı
3











