Comparison of marginal and internal adaptation of three-unit fixed dental prostheses made using CAD/CAM metal-free materials

dc.authoriddemirci, fatih/0000-0002-8744-5592
dc.authoridTUZLALI, MESUT/0000-0002-7602-8101
dc.authoridbaran, melike cigdem/0000-0002-6933-8259
dc.authorwosiddemirci, fatih/ABG-8682-2020
dc.authorwosidTUZLALI, MESUT/U-2324-2017
dc.contributor.authorBaran, Melike Cigdem
dc.contributor.authorDemirci, Fatih
dc.contributor.authorTuzlali, Mesut
dc.date.accessioned2024-08-04T20:53:12Z
dc.date.available2024-08-04T20:53:12Z
dc.date.issued2022
dc.departmentİnönü Üniversitesien_US
dc.description.abstractThe aim of this study was to compare the marginal and internal adaptation of three-unit fixed dental prostheses (FDPs) fabricated from different metal-free materials using CAD/CAM methods. A total of 100 three-unit FDPs were produced from a cubic zirconia, a fiber-reinforced resin composite, a polyetheretherketone (PEEK), a polyetherketoneketone (PEKK), and a polymer composite material by the CAD/CAM method (n = 20 per material). The zirconia group was considered the control/reference material. Marginal and internal gap values of the produced FDPs were measured using the silicone replica method at x40 magnification under a stereomicroscope. The obtained data were analyzed using one-way ANOVA and Tukey's HSD tests. The marginal and internal gap values for the cubic zirconia material were found to be statistically significantly lower than those seen for the PEEK, polymer composite, PEKK, and fiber-reinforced resin composite materials. While the marginal and internal adaptation of the cubic zirconia material was found to be better than the others, it should be noted that the marginal and internal gap values for all other materials tested were found to be within the clinically acceptable range.en_US
dc.description.sponsorshipInonu University Scientific Research Projects Unit [TDH-2021-2633]; Inonu University Scientific Research Projects Unit, Malatya,Turkeyen_US
dc.description.sponsorshipInonu University Scientific Research Projects Unit, Grant/Award Number:TDH-2021-2633This study was supported by grant No. TDH-2021-2633 from Inonu University Scientific Research Projects Unit, Malatya,Turkeyen_US
dc.identifier.doi10.1111/eos.12901
dc.identifier.issn0909-8836
dc.identifier.issn1600-0722
dc.identifier.issue6en_US
dc.identifier.pmid36428097en_US
dc.identifier.scopus2-s2.0-85142636137en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.urihttps://doi.org/10.1111/eos.12901
dc.identifier.urihttps://hdl.handle.net/11616/101018
dc.identifier.volume130en_US
dc.identifier.wosWOS:000890315800001en_US
dc.identifier.wosqualityQ4en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherWileyen_US
dc.relation.ispartofEuropean Journal of Oral Sciencesen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectfiber-reinforced resin compositeen_US
dc.subjectpolyetheretherketoneen_US
dc.subjectpolyetherketoneketoneen_US
dc.subjectprecisionen_US
dc.titleComparison of marginal and internal adaptation of three-unit fixed dental prostheses made using CAD/CAM metal-free materialsen_US
dc.typeArticleen_US

Dosyalar