Broken Rotor Bar Fault Monitoring based on Fluxgate Sensor Measurement of Leakage Flux

Küçük Resim Yok

Tarih

2017

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Ieee

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

Broken rotor bar fault in induction motors significantly affects the motor dynamic performance and increases the mechanical oscillations in torque and speed. Motor current signature analysis has widely been used to detect such fault, yet it has some shortcomings due to motor topology, stator winding and load type dependencies. In this paper, radial leakage flux which contains most critical fault related information is analyzed using a fluxgate sensor to detect broken bar fault in induction motors (IMs). The 2D-Time Stepping Finite Element Method (2D-TSFEM) is used to analyze fault patterns in leakage flux. A 2-Dimensional (2D) finite element analysis and experimental results show that using leakage flux can provide superior and more reliable results than classical motor stator current analysis in IMs.

Açıklama

IEEE International Electric Machines and Drives Conference (IEMDC) -- MAY 20-24, 2017 -- Miami, FL

Anahtar Kelimeler

Broken rotor bar, fault diagnosis, fluxgate sensors, leakage flux component

Kaynak

2017 Ieee International Electric Machines and Drives Conference (Iemdc)

WoS Q Değeri

N/A

Scopus Q Değeri

N/A

Cilt

Sayı

Künye