Determination of Bisphenol a with Poly (p-Aminobenzoic Acid) Modified Gold Electrode by Using Differential Pulse Voltammetry

dc.contributor.authorTitretir Duran, Serap
dc.date.accessioned2021-04-07T11:06:14Z
dc.date.available2021-04-07T11:06:14Z
dc.date.issued2019
dc.departmentİnönü Üniversitesien_US
dc.description.abstractAbstract: Bisphenol A (BPA) is important matter in chemical industry used in the produce of some food contact materials such as plastics, adhesives and coatings. But BPA has also some toxic effects for human endocrine system and environment. Therefore, novel sensitive and selective methods for determination the level of BPA in environmental, medical samples and foods new measurement methods need to be developed. A novel, sensitive, simple and cheap electrochemical sensor based on poly (p-aminobenzoic acid) p(p-ABA) modified gold electrode (AuE) was developed for the measurement of BPA in water samples. Firstly, AuEs were modified with polymerization of the p-amino benzoic acid as a monomer by using bulk electrolysis in 0.01 M HCl at -250 mV. Then the electrochemical oxidation of BPA carried out in 0.1 M phosphate buffer solution (PBS) pH=6 on p(p-ABA) modified AuE. The effects of various electrochemical parameters, such as scan rate, electroyte type and electrolyte pH were examined. Differential pulse voltammetry (DPV) was used as an ideal analytical method for the qualitative and quantitative detect of BPA in water samples. The developed electrochemical sensor has linear signal to BPA in the range of 2–100 ?M. Prepared electrode was showed the limit of detection (LOD) of 0.26 µM and R2 of 0.999. Additionally, the developed sensor s used to determination the BPA in bottled drinking water sold in Turkish markets by using DPV, and obtains satisfactory results. The recovery values of the bottle water samples in the freezer, at room temperature and in the car were calculated as 102.22%, 104.68% and 106.06% respectively.en_US
dc.identifier.citationDURAN S. T (2019). Determination of Bisphenol a with Poly (p-Aminobenzoic Acid) Modified Gold Electrode by Using Differential Pulse Voltammetry. Gazi University Journal of Science, 32(2), 426 - 438.en_US
dc.identifier.endpage438en_US
dc.identifier.issn2147-1762
dc.identifier.issue2en_US
dc.identifier.startpage426en_US
dc.identifier.trdizinid324420en_US
dc.identifier.urihttps://hdl.handle.net/11616/33395
dc.identifier.urihttps://search.trdizin.gov.tr/yayin/detay/324420
dc.identifier.volume32en_US
dc.identifier.wosWOS:000471792600004en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakTR-Dizinen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.language.isoenen_US
dc.relation.ispartofGazi University Journal of Scienceen_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleDetermination of Bisphenol a with Poly (p-Aminobenzoic Acid) Modified Gold Electrode by Using Differential Pulse Voltammetryen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Makale Dosyası.pdf
Boyut:
807.91 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale Doyası
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.71 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: