dc.description.abstractAim: ;The aim of this study was to evaluate the degree of conversion (DC) of composite resin at different depths of simulated immature root canals using light-transmitting plastic post (LTPP) and three different light sources. Methodology: ;Composite resin was packed into 60 black plastic cylinders 12 mm in length with 4 mm internal diameters to simulate immature root canals. LTPPs were inserted into half of the simulated canals and the other half acted as controls. Both the simulated canals with LTPPs and the controls were divided into three groups of 10, and each group was cured using either a quartz-tungsten-halogen (QTH), light-emitting diode (LED), or plasma arc (PAC) curing unit. Specimens were sectioned in three horizontally 24 h after curing to represent cervical, middle, and apical levels. DC for each section of composite resin was measured using a Fourier transform infrared spectrophotometer, and data were analyzed using three-way anova and Tukey tests. Results: ;At the cervical level, no significant differences were found between specimens cured using different light sources or between specimens with and without LTPPs (P > 0.05). However, DC was significantly higher in specimens with LTPPs than in those without LTPPs at both the middle and apical levels (P < 0.05). The mean DC of all specimens with LTPPs was significantly higher than that of specimens without LTPPs (P < 0.05). PAC unit showed lower DC than QTH and LED units at both the middle and apical levels; however, the differences were not statistically significant (P > 0.05). Conclusions: ;The results of this study suggest that the use of a LTPP increased the DC of composite resin at the middle and apical levels of simulated immature root canals, but that DC was independent of type of light source.en_US
dc.description.sponsorshipKirikkale University Scientific Project Research Foundation, Turkeyen_US
dc.description.sponsorshipThis study was supported by a grant-in-aid (2007-17) from the Kirikkale University Scientific Project Research Foundation, Turkey. We thank Dr Duygu Ekinci for FTIR analysis of the manuscript.en_US
dc.identifier.doi10.1111/j.1600-9657.2011.00987.x
dc.identifier.endpage198en_US
dc.identifier.issn1600-4469
dc.identifier.issue3en_US
dc.identifier.pmid21457186en_US
dc.identifier.scopus2-s2.0-79955905658en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.startpage195en_US
dc.identifier.urihttps://doi.org/10.1111/j.1600-9657.2011.00987.x
dc.identifier.urihttps://hdl.handle.net/11616/95324
dc.identifier.volume27en_US
dc.identifier.wosWOS:000290541400007en_US
dc.identifier.wosqualityQ3en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherWiley-Blackwellen_US
dc.relation.ispartofDental Traumatologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectFiber-Posten_US
dc.subjectCureen_US
dc.subjectPolymerizationen_US
dc.subjectHardnessen_US
dc.subjectCementen_US
dc.subjectTimeen_US
dc.subjectSpectroscopyen_US
dc.subjectFractureen_US
dc.titleEffect of different light sources in combination with a light-transmitting post on the degree of conversion of resin composite at different depths of simulated root canalsen_US
dc.typeArticleen_US

Dosyalar