Amperometric Simultaneous Measurement of Copper and Cobalt Ions with Polythiophene Incorporating Pendant Terpyridine Groups

dc.authoridKuyumcu Savan, Ebru/0000-0002-8851-0907
dc.authoridERDOGDU, GAMZE/0000-0002-8114-6946
dc.authoridSEÇKİN, Turgay/0000-0001-8483-7366
dc.authoridKoytepe, Suleyman/0000-0002-4788-278X
dc.authoridPASAHAN, Aziz/0000-0002-0657-3884
dc.authorwosidKuyumcu Savan, Ebru/E-3430-2019
dc.authorwosidERDOGDU, GAMZE/ABG-7776-2020
dc.authorwosidPAŞAHAN, Aziz/ABI-3519-2020
dc.authorwosidKöytepe, Süleyman/AAA-4168-2021
dc.authorwosidSEÇKİN, Turgay/ABG-7537-2020
dc.contributor.authorSavan, Ebru Kuyumcu
dc.contributor.authorKoytepe, Suleyman
dc.contributor.authorPasahan, Aziz
dc.contributor.authorErdogdu, Gamze
dc.contributor.authorSeckin, Turgay
dc.date.accessioned2024-08-04T20:39:55Z
dc.date.available2024-08-04T20:39:55Z
dc.date.issued2014
dc.departmentİnönü Üniversitesien_US
dc.description.abstractTerpyridine containing thiophene monomer was synthesized. Electrochemical behavior of the monomer was studied by cyclic voltammetry. This monomer was polymerized via electrochemical methods and the resultant polymer was characterized. The stepwise fabrication process of the polymeric film electrode and its electrochemical sensing performance towards simultaneously Co and Cu ions were evaluated. The sensing parameters of the polymer electrode were investigated in detail, and the determination conditions were optimized. Under the optimal conditions, sensor response peak is linear to the Co ion concentration in the range of 1.0-50.0 mu M and the Cu ion concentration in the range of 1.0-20.0 mu M. Detection limit of terpyridine-based polythiophene film electrode for Co and Cu is respectively 100 nM and 0.05 nM.en_US
dc.description.sponsorshipTUBITAK - The Scientific and Technological Research Council of Turkey [MAG110M751]en_US
dc.description.sponsorshipThe authors would like to thank TUBITAK - The Scientific and Technological Research Council of Turkey for the financial support with the project number MAG110M751.en_US
dc.identifier.doi10.1080/03602559.2014.935405
dc.identifier.endpage1824en_US
dc.identifier.issn0360-2559
dc.identifier.issn1525-6111
dc.identifier.issue17en_US
dc.identifier.scopus2-s2.0-84910597365en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.startpage1817en_US
dc.identifier.urihttps://doi.org/10.1080/03602559.2014.935405
dc.identifier.urihttps://hdl.handle.net/11616/96593
dc.identifier.volume53en_US
dc.identifier.wosWOS:000350410200008en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherTaylor & Francis Incen_US
dc.relation.ispartofPolymer-Plastics Technology and Engineeringen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectElectropolymerizationen_US
dc.subjectMetal ion sensoren_US
dc.subjectTerpyridineen_US
dc.titleAmperometric Simultaneous Measurement of Copper and Cobalt Ions with Polythiophene Incorporating Pendant Terpyridine Groupsen_US
dc.typeArticleen_US

Dosyalar