Evaluation of corneal biomechanical properties after uneventful standard coaxial phacoemulsification surgery

dc.contributor.authorDoğanay, Selim
dc.contributor.authorFırat, Penpe Gül
dc.contributor.authorDoğanay, Derya
dc.contributor.authorUlaş, Fatih
dc.contributor.authorÇankaya, Cem
dc.date.accessioned2021-11-09T16:35:20Z
dc.date.available2021-11-09T16:35:20Z
dc.date.issued2018
dc.departmentİnönü Üniversitesien_US
dc.description.abstractAbstract: Aim: This study was designed to investigate the alteration of intraocular pressure measurements and biomechanical properties of the cornea in patients who underwent uneventful standard coaxial phacoemulsification cataract surgery through 2.75 mm corneal main incision with intraocular lens implantation. Material and Methods: 15 eyes of 15 patients admitted to our clinic because of the cataract problems in the study. Corneal hysteresis (CH), corneal resistance factor (CRF) measurements, Goldmann correlated (IOPg), and corneal compensated intraocular pressure (IOPcc) values were recorded by ocular response analyzer (ORA) before and 1 day, 1 week and 1 month after surgery. Results: The mean age of the patients was 64.3 ± 8.06 years. Preoperative mean CH, CRF, IOPg and IOPcc values were 8.23±2.10, 9.33±2.27, 18.54±3.42 and 19.66±3.22, respectively. The mean CH, CRF, IOPg and IOPcc values were 5.50±2.07, 8.69±2.04, 22.29±3.37 and 23.83±3.32, respectively on the first day after the surgery. The mean CH, CRF, IOPg and IOPcc values were 5.25±1.83, 8.29±2.10, 18.86±2.72 and 20.20±3.37, respectively of the first week after the surgery. The mean CH, CRF, IOPg and IOPcc values were 7.88±1.99, 8.37±1.83, 15.81±2.60 and 16.41±2.80, respectively in the first month after the surgery. Conclusion: These results revealed that the biomechanical properties of the cornea may change during the first one month period after uneventful standard coaxial phacoemulsification surgery.en_US
dc.identifier.citationÇANKAYA C,ULAŞ F,DOĞANAY D. ',FIRAT P,DOĞANAY S (2018). Evaluation of corneal biomechanical properties after uneventful standard coaxial phacoemulsification surgery. Annals of Medical Research, 25(2), 180 - 183. Doi: 10.5455/jtomc.2017.12.159en_US
dc.identifier.doi10.5455/jtomc.2017.12.159en_US
dc.identifier.endpage183en_US
dc.identifier.issn2636-7688
dc.identifier.issue2en_US
dc.identifier.startpage180en_US
dc.identifier.trdizinid285495en_US
dc.identifier.urihttps://doi.org/10.5455/jtomc.2017.12.159
dc.identifier.urihttps://hdl.handle.net/11616/43054
dc.identifier.urihttps://search.trdizin.gov.tr/yayin/detay/285495
dc.identifier.volume25en_US
dc.indekslendigikaynakTR-Dizinen_US
dc.language.isoenen_US
dc.relation.ispartofAnnals of Medical Researchen_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleEvaluation of corneal biomechanical properties after uneventful standard coaxial phacoemulsification surgeryen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
Öz.docx
Boyut:
18.43 KB
Biçim:
Microsoft Word XML
Açıklama:
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.71 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: