The effect of nitrous oxide diffusion on laryngeal mask airway cuff inflation in children
dc.contributor.author | Algren, JT | |
dc.contributor.author | Gursoy, F | |
dc.contributor.author | Johnson, TD | |
dc.contributor.author | Skjonsby, BS | |
dc.date.accessioned | 2024-08-04T20:11:58Z | |
dc.date.available | 2024-08-04T20:11:58Z | |
dc.date.issued | 1998 | |
dc.department | İnönü Üniversitesi | en_US |
dc.description | American-Society-of-Anesthesiologists Annual Meeting -- OCT 15-22, 1994 -- SAN FRANCISCO, CALIFORNIA | en_US |
dc.description.abstract | We studied the effect of nitrous oxide (N2O) diffusion on size 2 LMA cuff inflation in 52 children, 38+/-21 months of age. LMA cuffs were inflated with air (Group A) or 65% N2O, oxygen and halothane (Group B). Cuffs were inflated in a stepwise manner, achieving a cuff leak pressure of 17+/-4 cm H2O for all patients. Cuff volume and intracuff pressure increased in Group A (8.5+/-1.0 mi to 10.8+/-1.4 mi and 101+/-36 mmHg to 152+/-42 mmHg, respectively) and decreased in Group B (8.9+/-1.0 mi to 6.6+/-1.5 mi and 90+/-30 mmHg to 53+/-37 mmHg, respectively). Cuff leak pressure did not change significantly in either group. We conclude that cuff inflation with a mixture of N2O/oxygen prevents N2O diffusion into the cuff, avoiding cuff overinflation without compromising LMA function. | en_US |
dc.description.sponsorship | Amer Soc Anesthesiologists | en_US |
dc.identifier.doi | 10.1046/j.1460-9592.1998.00696.x | |
dc.identifier.endpage | 36 | en_US |
dc.identifier.issn | 1155-5645 | |
dc.identifier.issue | 1 | en_US |
dc.identifier.pmid | 9483595 | en_US |
dc.identifier.scopus | 2-s2.0-0031915099 | en_US |
dc.identifier.scopusquality | Q2 | en_US |
dc.identifier.startpage | 31 | en_US |
dc.identifier.uri | https://doi.org/10.1046/j.1460-9592.1998.00696.x | |
dc.identifier.uri | https://hdl.handle.net/11616/93120 | |
dc.identifier.volume | 8 | en_US |
dc.identifier.wos | WOS:000072005600007 | en_US |
dc.identifier.wosquality | Q2 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.indekslendigikaynak | PubMed | en_US |
dc.language.iso | en | en_US |
dc.publisher | Blackwell Science Ltd | en_US |
dc.relation.ispartof | Paediatric Anaesthesia | en_US |
dc.relation.publicationcategory | Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | laryngeal mask airway (LMA) | en_US |
dc.subject | LMA cuff overinflation | en_US |
dc.subject | nitrous oxide diffusion | en_US |
dc.title | The effect of nitrous oxide diffusion on laryngeal mask airway cuff inflation in children | en_US |
dc.type | Conference Object | en_US |