Correlation between intraocular pressure obtained with water drinking test versus modified diurnal tension curve measurement in pseudoexfoliation glaucoma

dc.authoridBozgul, Pembegul/0000-0002-9427-3610
dc.authoridTuncer Firat, Ilknur/0000-0003-1491-8659
dc.authoridFirat, Murat/0000-0001-6040-9332
dc.authorwosiddikci, seyhan/A-3311-2019
dc.authorwosidÖztürk, Emrah/H-5241-2017
dc.authorwosidBozgul, Pembegul/AAQ-4951-2020
dc.contributor.authorFirat, Penpe Gul
dc.contributor.authorDikci, Seyhan
dc.contributor.authorFirat, Ilknur Tuncer
dc.contributor.authorDemirel, Soner
dc.contributor.authorFirat, Murat
dc.contributor.authorOzturk, Emrah
dc.contributor.authorGok, Zarife Ekici
dc.date.accessioned2024-08-04T20:49:29Z
dc.date.available2024-08-04T20:49:29Z
dc.date.issued2021
dc.departmentİnönü Üniversitesien_US
dc.description.abstractPurpose The aim of this paper was to study the correlation and agreement between the intraocular pressure (IOP) peak value and fluctuations detected with the modified diurnal tension curve (mDTC) and the water drinking test (WDT) in pseudoexfoliation glaucoma (XFG) patients. Methods This prospective observational study enrolled 42 eyes of 42 XFG patients. The IOPs were measured at 2-h intervals from 8 am to 4 pm with a Goldmann applanation tonometer by a single observer to establish the mDTC. The WDT was then performed between 4 and 5 pm on the same day and the IOP was measured 4 times at 15-min intervals after water ingestion. The IOPpeak, IOPmean, IO (min), and IOPfluctuation were measured with both the mDTC and WDT. The paired sample t test, Spearman's correlation coefficient and Bland-Altman plots were used for statistical analysis. Results The mean age of the 42 patients consisting of 24 females and 18 males was 66.9 +/- 6.8 years, and the mean central corneal thickness was 517.7 +/- 29.1 mu m. The mean values with the mDTC and WDT measurements were 15.05 +/- 2.75 mmHg and 17.17 +/- 3.25 mmHg (p <= 0.0001, r = 0.884) for IOPmean, 16.76 +/- 3.45 mmHg and 18.92 +/- 3.94 mmHg (p <= 0.0001, r=0.787) for IOPpeak, and 13.61 +/- 2.56 mmHg and 15.11 +/- 2.84 mmHg (p <= 0.0001, r=0.824) for IOPmin, respectively, and a positive correlation was present between these values. Conclusion There was a positive correlation between the peak, minimum, and mean IOP values determined using the mDTC and WDT in treated XFG patients. WDT can be used as an alternative in the assessment of the IOP in these patients as a more practical method.en_US
dc.identifier.doi10.1007/s10792-021-01847-5
dc.identifier.endpage2886en_US
dc.identifier.issn0165-5701
dc.identifier.issn1573-2630
dc.identifier.issue8en_US
dc.identifier.pmid33877501en_US
dc.identifier.scopus2-s2.0-85104560658en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage2879en_US
dc.identifier.urihttps://doi.org/10.1007/s10792-021-01847-5
dc.identifier.urihttps://hdl.handle.net/11616/99893
dc.identifier.volume41en_US
dc.identifier.wosWOS:000641654500002en_US
dc.identifier.wosqualityQ3en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherSpringeren_US
dc.relation.ispartofInternational Ophthalmologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectGlaucomaen_US
dc.subjectPseudoexfoliationen_US
dc.subjectDiurnal tension curveen_US
dc.subjectWater drinking testen_US
dc.titleCorrelation between intraocular pressure obtained with water drinking test versus modified diurnal tension curve measurement in pseudoexfoliation glaucomaen_US
dc.typeArticleen_US

Dosyalar