The misalignment fault is commonly caused by incorrect shaft positions between motor and load in electrical machines. It affects the mechanical symmetry of machine and thus causes mechanical oscillation on the shaft. In this paper, the parallel misalignment fault is analyzed based on stator current, vibration and stray flux in induction motors (IMs). The three-axis vibration sensor and an integrated flux sensor are used in order to stream vibration and stray flux for diagnostics process, respectively. The comparative results between stator current, vibration and stray flux are presented. Experimental results show that stator current and vibration-based analyses provide highly reliable results than stray flux for parallel misalignment fault. It is also shown that the proposed signatures in current and vibration vary very little with respect to load and motor drive type. Moreover, Multilayer Perceptron (MLP) based machine learning algorithm using vibration and stator current is carried out and it has excellent performance in the automatic detection of parallel misalignment fault.

Açıklama

13th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives (SDEMPED) -- AUG 22-25, 2021 -- Dallas, TX

Anahtar Kelimeler

Misalignment fault, fault diagnosis, induction motor, stray flux, vibration, Multi-layer perceptron

Kaynak

2021 Ieee 13th International Symposium on Diagnostics For Electrical Machines, Power Electronics and Drives (Sdemped)

WoS Q Değeri

N/A

Scopus Q Değeri

N/A

Cilt

Sayı

Künye