dc.description.abstractPURPOSE. The aim of this study is to compare the casts obtained by using conventional techniques and liquid crystal display (LCD) three-dimensional (3D) print techniques in the All-on-4 treatment concept of the edentulous mandibular jaw. MATERIALS AND METHODS. In this study, a completely edentulous mandibular acrylic cast (typodont) with bone-level implants placed with the All -on-4 technique served as a reference cast. In this typodont, impressions were taken with the conventional technique and dental stone casts were obtained. In addition, after scanning the acrylic cast in a dental laboratory scanner and obtaining the Standard Tessellation Language (STL) data, 3D printed casts were manufactured with a 3D printing device based on the design. The stone and 3D printed casts were scanned in the laboratory scanner and STL data were obtained, and then the interimplant distances were measured using Geomagic Control X v2020 (3D Systems, Rock Hill, SC, USA) analysis software (n = 60). The obtained data were statistically evaluated with one-way analysis of variance (ANOVA) and Tukey's pairwise comparison tests. RESULTS. As a result of the one-way ANOVA test, it was determined that the stone casts, 3D printed casts, and reference cast values in all distance intervals conformed to the normal distribution and these values had a significant difference among them in all distance intervals. In Tukey pairwise comparison test, significant differences were found between casts at all distance intervals. In all analyses, the level of significance was determined as .05. CONCLUSION. 3D printed casts obtained with a 3D LCD printing device can be an alternative to stone casts when implants are placed in edentulous jaws. [J Adv Prosthodont 2022;14:379-87]en_US
dc.description.sponsorshipInonu University Scientific Research Projects Unit, Malatya, Turkey [TDH-2021-2668]en_US
dc.description.sponsorshipThis study was supported by grant No. TDH-2021-2668 from Inonu University Scientific Research Projects Unit, Malatya, Turkey.en_US
dc.identifier.doi10.4047/jap.2022.14.6.379
dc.identifier.endpage387en_US
dc.identifier.issn2005-7806
dc.identifier.issn2005-7814
dc.identifier.issue6en_US
dc.identifier.pmid36685787en_US
dc.identifier.scopus2-s2.0-85145842239en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpage379en_US
dc.identifier.urihttps://doi.org/10.4047/jap.2022.14.6.379
dc.identifier.urihttps://hdl.handle.net/11616/101100
dc.identifier.volume14en_US
dc.identifier.wosWOS:000960868400005en_US
dc.identifier.wosqualityQ3en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherKorean Acad Prosthodonticsen_US
dc.relation.ispartofJournal of Advanced Prosthodonticsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAccuracyen_US
dc.subjectAll-on-4en_US
dc.subjectDental implanten_US
dc.subjectDigital dentistryen_US
dc.subjectThree-dimensional printingen_US
dc.titleEvaluation of the accuracy of dental casts manufactured with 3D printing technique in the All-on-4 treatment concepten_US
dc.typeArticleen_US

Dosyalar