Longitudinal pulmonary functional loss in cotton textile workers: A 5-year follow-up study

dc.authoridKilic, Talat/0000-0001-8125-9062;
dc.authorwosidEkerbiçer, Hasan Çetin/HHT-0237-2022
dc.authorwosidKoksal, Nurhan/AAA-3249-2022
dc.authorwosidKilic, Talat/ABI-4457-2020
dc.authorwosidKöksal, Nurhan/AAG-5849-2021
dc.contributor.authorKahraman, Hasan
dc.contributor.authorSucakli, Mustafa Haki
dc.contributor.authorKilic, Talat
dc.contributor.authorCelik, Mustafa
dc.contributor.authorKoksal, Nurhan
dc.contributor.authorEkerbicer, Hasan Cetin
dc.date.accessioned2024-08-04T20:38:00Z
dc.date.available2024-08-04T20:38:00Z
dc.date.issued2013
dc.departmentİnönü Üniversitesien_US
dc.description.abstractBackground: Occupational exposure to cotton dust causes several diseases affecting the lungs, but only limited information is available on effects of long-term exposure. In this study, we aimed to evaluate longitudinal changes in selected parameters of pulmonary function in textile workers. Material/Methods: This prospective cohort study began with 196 textile workers in 2006 and was completed in 2011 with 49 workers. We used standardized tests for pulmonary function on participants on the first day of the workweek in June of 2006 and 2011. Environmental samples of cotton dust were gathered with a vertical elutriator. Loss of pulmonary function was assessed based on gender and smoking status. Results: The mean number of years participants worked in the textile factory was 7.61 +/- 1.83 years, and the mean age was 35.3+5.8 years. The annual FEV1 loss of all workers was 53.2 ml, giving a ratio of annual FEV1 loss to baseline FEV1 of 1.4%. Pulmonary function parameters of all participants in 2011 were significantly lower than those in 2006 (for all, p<0.05). In both surveys, pulmonary function in current smokers was lower, but this difference was not significant (p>0.05). Conclusions: This study provides the first data on pulmonary functional loss in Turkish textile workers and supports the findings of other cohort studies that workers with long-term exposure to cotton dust may lose some pulmonary function. The ratio of annual FEV1 loss to baseline FEV1 appears to be a more accurate and comparable method than annual FEV1 loss for evaluating pulmonary functional loss.en_US
dc.identifier.endpage1182en_US
dc.identifier.issn1643-3750
dc.identifier.pmid24346118en_US
dc.identifier.scopus2-s2.0-84890484775en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage1176en_US
dc.identifier.urihttps://hdl.handle.net/11616/96307
dc.identifier.volume19en_US
dc.identifier.wosWOS:000328580000001en_US
dc.identifier.wosqualityQ3en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherInt Scientific Literature, Incen_US
dc.relation.ispartofMedical Science Monitoren_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjecttextileen_US
dc.subjectoccupational healthen_US
dc.subjectrespiratoryen_US
dc.subjectorganic dustsen_US
dc.subjectpulmonary functionen_US
dc.titleLongitudinal pulmonary functional loss in cotton textile workers: A 5-year follow-up studyen_US
dc.typeArticleen_US

Dosyalar