Evaluation of Pentacam-Scheimpflug imaging of anterior segment parameters in patients with pseudoexfoliation syndrome and pseudoexfoliative glaucoma

dc.authoridcankaya, cem/0000-0002-7716-0438
dc.authoridBozgul, Pembegul/0000-0002-9427-3610
dc.authoridYologlu, Saim/0000-0002-9619-3462;
dc.authorwosidcankaya, cem/ABH-6458-2020
dc.authorwosidBozgul, Pembegul/AAQ-4951-2020
dc.authorwosidYologlu, Saim/ABI-8014-2020
dc.authorwosidCankaya, Cem/HTR-3803-2023
dc.contributor.authorDoganay, Selim
dc.contributor.authorTasar, Ahmet
dc.contributor.authorCankaya, Cem
dc.contributor.authorFirat, Penpe Gul
dc.contributor.authorYologlu, Saim
dc.date.accessioned2024-08-04T20:35:47Z
dc.date.available2024-08-04T20:35:47Z
dc.date.issued2012
dc.departmentİnönü Üniversitesien_US
dc.description.abstractBackground: The aim was to evaluate anterior segment parameters in patients with pseudoexfoliation syndrome (PXS) or pseudoexfoliative glaucoma (PXG) with the Pentacam-Scheimpflug imaging system. Methods: Eighty eyes of 53 patients with PXS (Group 1), 80 eyes of 57 patients with PXG (Group 2) and 80 eyes of 45 control cases (Group 3) were included in the study. Anterior chamber depth, volume (ACV), angle (ACA) width, central corneal thickness (CCT), central 3.0, 5.0 and 7.0 mm corneal volumes and pupil diameters were compared between groups. Results: Although anterior chamber depths in the PXG group were significantly lower than the control group (p < 0.05), there was no statistically significant difference between the PXS group and the control group in means of anterior chamber depth values (p > 0.05). There were no statistically significant differences among PXS, PXG and the control group in mean values of ACV, ACA width, CCT, pupil diameters and central 3.0, 5.0 and 7.0 mm corneal volume (p > 0.05). Conclusions: The anterior chamber depths of PXG patients were lower than those of healthy individuals. Although the difference in anterior chamber depth between PXG patients and normal patients was statistically significant, this finding is unlikely to be of clinical significance. The anterior chamber depths of PXS patients were similar to those of healthy individuals. There were no significant differences in the means of ACV, ACA width, CCT, pupil diameter and corneal volume values on central 3.0, 5.0 and 7.0 mm among patients with PXS, PXG and healthy individuals.en_US
dc.identifier.doi10.1111/j.1444-0938.2011.00691.x
dc.identifier.endpage222en_US
dc.identifier.issn0816-4622
dc.identifier.issn1444-0938
dc.identifier.issue2en_US
dc.identifier.pmid22321056en_US
dc.identifier.scopus2-s2.0-84857801590en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpage218en_US
dc.identifier.urihttps://doi.org/10.1111/j.1444-0938.2011.00691.x
dc.identifier.urihttps://hdl.handle.net/11616/95588
dc.identifier.volume95en_US
dc.identifier.wosWOS:000300979300015en_US
dc.identifier.wosqualityQ3en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherWileyen_US
dc.relation.ispartofClinical and Experimental Optometryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectanterior chamber angleen_US
dc.subjectanterior chamber depthen_US
dc.subjectcentral corneal thicknessen_US
dc.subjectcorneal volumeen_US
dc.subjectglaucomaen_US
dc.subjectpseudoexfoliationen_US
dc.subjectpupilen_US
dc.subjectScheimpflug imaging systemen_US
dc.titleEvaluation of Pentacam-Scheimpflug imaging of anterior segment parameters in patients with pseudoexfoliation syndrome and pseudoexfoliative glaucomaen_US
dc.typeArticleen_US

Dosyalar