Yüksek Doz İnhale Fluticasone Propionate Ve Budesonide İn Astımlı Hastalarda Sistemik Yan Etki Potansiyellerinin Karşılaştırılması

dc.contributor.authorGunen, Hakan
dc.date.accessioned2015-06-16T07:56:54Z
dc.date.available2015-06-16T07:56:54Z
dc.date.issued2000
dc.departmentİnönü Üniversitesien_US
dc.descriptionTurgut Özal Tıp Merkezi Dergisi.7 (1) :125-128,2000. Malatyaen_US
dc.description.abstractÇalışmamızda astım tedavisinde en çok tercih ediien inhale kortikosteroidler (KS) olan Fluticasone Propionate (FP) ve Budesonide (B)'in sistemik yan etki yapma potansiyellerini sabah ölçülen plazma kortizol düzeylerine bakarak karşılaştırmayı amaçladık. Materyal ve Metot: Çalışmaya en az 6 aydır minimum 1000 mcg/gün inhale FP (n=33) veya B (n=36) kullanan toplam 69 orta-persistan veya Heri evre astımlı hasta dahii edildi. Bulgular: FP kullanan 1. gruptaki hastaiann yaş ortalaması 49.2±15.2 yıl, B kullanan 2. gruptaki hastaların yaş ortalaması ise 48.1±12.2 yıl idi (p>0.05). Hastaların tamamı en az 20 gündür hiçbir sistemik ilaç kullanmıyordu. Sabah kortizol düzeyi ölçümleri 08.00 ve 09.00 arasında yapıldı. Birinci grubun ortalama sabah kortizol değeri 10.3±4.6 mcg/dl, 2. grubunki ise 10.4±5.4 mcg/di seviyesindeydi (p>0.05). Kontrol grubu olarak alınan 20 kişilik herhangi bir Haç kullanmayan yaşça benzer sağlıklı hastane personelinin ortalama sabah kortizol düzeyi ise 16.0±5.3 mcg/dl olup, 1. grubun ortalama kortizol düzeyleri kontrol grubuna göre istatistiki olarak anlamlı derecede düşüktü (pO.Ol). 1. gruptaki 4 hastanın (%12.1), 2. gruptaki 6 hastanın (%16.7) sabah plazma kortizol düzeyleri klinik olarak önemli sonuçlar doğurabilecek kadar düşük ölçülürken, kontrol grubunda bu derecede düşük bir değere rastlanmadı. Çalışmamızda yüksek doz inhale FP ve B kullanan astımlı hasta gruplan arasında sistemik yan etkilere yol açma potansiyeli açısından fark bulunmazken (p>0.05); FP kullanan hastaların %12.1'inde ve B kullananların ise %16.7'sinde ciddi klinik sonuçlar doğurabilecek derecede düşük kortizol seviyeleri tesbit edildi. Sonuç: Biz bu tip yüksek doz inhale steroid kullanan ve sistemik yan etkilere karşı hassas hastaiann önceden saptanabilmesi amacı ile belli aralıklarla sabah kortizol düzeylerinin ölçülmesi gerektiğini düşünüyoruz.en_US
dc.description.abstractIn our study, we aimed to compare the potential for systemic side effects of two most frequently preferred inhaled corticosteroids (CS) in the treatment of asthma, Fluticasone Propionate (FP) and Budesonide (B), by evaluating morning plasma cortisol levels. Materials and method: The study Included 69 moderate-persistent and severe asthmatic patients using minimal 1000 mcg/day FP (n=33) or B (n=36) for at least 6 months. The mean age of the patients was 49.2±15.2 years in the f* group using FP, and was 48.1 ±12.2 years (p>0.0S) in the 2ld group using B. Patients were not utilizing any systemic drugs for the last 20 days and their morning plasma cortisol level measurements were performed between 08.00 and 09.00 a.m. Results: Mean plasma cortisol level of the f group was 10.3±4.6 mcg/dl and that of the 2ld group was 10.4±5.4 mcg/dl (pX>.05). Mean plasma cordsol level of the age matched healthy hospital persone/i was 16.0±5.3 mcg/di and the mean cortisol level of the 1st group was significantly lower than the control group (pO.Ol). Four patients (12.1%) in the 1st group and six patients (16.7%) in the 2™* group had extremely low plasma cortisol levels, but such low levels were not measured in the control group at all. Conclusion: We could not define any difference between asthmatic patient groups utilising FP and B regarding their potentials for systemic side effects (p>0.05); on the other hand 12.1 % of the patients utilising FP and 16.7 % of the patients utilising B had extremely low plasma levels of cortisol, which could lead to clinically important outcomes. We think that early morning plasma cortisol levels should be measured at certain intervals in patients utilising high dose of inhaled CS to detect the patients vulnerable to systemic side effects.en_US
dc.identifier.citationGunen, H.;Turgut Özal Tıp Merkezi Dergisi.7 (1) :125-128,2000. Malatya.en_US
dc.identifier.endpage128en_US
dc.identifier.issn1300-1744
dc.identifier.issue2en_US
dc.identifier.startpage125en_US
dc.identifier.trdizinid11060en_US
dc.identifier.urihttps://hdl.handle.net/11616/2271
dc.identifier.urihttp://www.totmdergisi.org/articles/2000/volume7/issue2/2000_7_2_7.pdf
dc.identifier.urihttps://search.trdizin.gov.tr/yayin/detay/11060
dc.identifier.volume7en_US
dc.indekslendigikaynakTR-Dizinen_US
dc.language.isotren_US
dc.publisherTurgut Özal Tıp Merkezi Dergisien_US
dc.relation.ispartofİnönü Üniversitesi Turgut Özal Tıp Merkezi Dergisien_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsAttribution 3.0 United States*
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/us/*
dc.subjectAstımen_US
dc.subjectsistemik yan etkileren_US
dc.subjectfluticasone propionateen_US
dc.subjectbudesonideen_US
dc.subjectAsthmaen_US
dc.subjectsystemic side effectsen_US
dc.subjectfluticasone propionateen_US
dc.subjectbudesonideen_US
dc.titleYüksek Doz İnhale Fluticasone Propionate Ve Budesonide İn Astımlı Hastalarda Sistemik Yan Etki Potansiyellerinin Karşılaştırılmasıen_US
dc.title.alternativeComparison of potential for systemic side effects with high dose inhaled fluticasone propionate and budesonide in asthmatic patientsen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
2000_7_2_7.pdf
Boyut:
191.17 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale Dosyası
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.71 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: