Comparison of plain and indoline modified mercury film electrodes for determination of lead, cadmium and copper in urine samples by anodic stripping voltammetry

dc.authorwosidDURAN, SERAP TİTRETİR/AAF-7927-2020
dc.contributor.authorDuran, Serap Titretir
dc.contributor.authorKaragozler, A. Ersin
dc.date.accessioned2024-08-04T20:45:23Z
dc.date.available2024-08-04T20:45:23Z
dc.date.issued2019
dc.departmentİnönü Üniversitesien_US
dc.description.abstractThe objective of this work is to assess response characteristics of conventional mercury film (MFE) and (poly)indoline modified mercury film electrodes (ICMFE) in determination of Cu, Pb and Cd ions by voltammetric stripping analysis. Parameters regarding to mercury and polymer film formations (such as potential, electrochemical mode chosen for film growth, polymer and mercury film thicknesses) and supporting electrolyte type and pH in stripping analysis were thoroughly studied, and conditions providing the highest and most stable responses for the three test metal ions were determined for both electrode types. Performances of the electrodes were evaluated in terms of sensitivity and selectivity in both synthetic aqueous solutions and urine samples. Responses at ICMFE were invariably much lower compared to that obtained at plain MFE. Decomposition of urine samples by hot mineral acid gave rise to enhanced responses at both electrodes. However, ICMFE always exhibited negative selectivity toward Cd even in acid decomposed urine samples. Reliability of the concentration values calculated by the method of standard addition in complex matrices, such as urine, was discussed comprehensively on statistical basis.en_US
dc.identifier.doi10.1007/s00289-018-2491-y
dc.identifier.endpage2425en_US
dc.identifier.issn0170-0839
dc.identifier.issn1436-2449
dc.identifier.issue5en_US
dc.identifier.scopus2-s2.0-85052681267en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage2411en_US
dc.identifier.urihttps://doi.org/10.1007/s00289-018-2491-y
dc.identifier.urihttps://hdl.handle.net/11616/98452
dc.identifier.volume76en_US
dc.identifier.wosWOS:000463611800016en_US
dc.identifier.wosqualityQ2en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherSpringeren_US
dc.relation.ispartofPolymer Bulletinen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectStripping voltammetryen_US
dc.subjectMercury film electrodeen_US
dc.subjectPolymer modified mercury film electrodeen_US
dc.subjectUrine sampleen_US
dc.subjectCuen_US
dc.subjectCden_US
dc.subjectPben_US
dc.subjectHeavy metal ionsen_US
dc.titleComparison of plain and indoline modified mercury film electrodes for determination of lead, cadmium and copper in urine samples by anodic stripping voltammetryen_US
dc.typeArticleen_US

Dosyalar