Assessment of ganglion cell complex, macular thickness, and optic disc parameters in keratoconus patients

dc.authoridBozgul, Pembegul/0000-0002-9427-3610
dc.authorwosidDoganay, Selim/AAH-6225-2021
dc.authorwosidorman, gözde/JEP-3740-2023
dc.authorwosidORMAN, GÖZDE/HNQ-4152-2023
dc.authorwosidBozgul, Pembegul/AAQ-4951-2020
dc.contributor.authorOrman, Gozde
dc.contributor.authorFirat, Penpe Gul
dc.contributor.authorDoganay, Selim
dc.contributor.authorDoganay, Derya
dc.date.accessioned2024-08-04T20:50:32Z
dc.date.available2024-08-04T20:50:32Z
dc.date.issued2020
dc.departmentİnönü Üniversitesien_US
dc.description.abstractPURPOSE: Keratoconus (KC) is bilateral noninflammatory corneal disorder characterized by progressive corneal thinning, protrusion, and scarring. The purpose of this study was to evaluate ganglion cell complex(GCC), macula thickness(MT) and optic head disc parameters in keratoconus patients. METHODS: A hospital based prospective clinical case series was performed in Inonu University School of Medicine. 52 eyes of 52 keratoconus patients and 50 eyes of 50 normal patients were enrolled. RESULTS: There is no statistically significant in MT between groups. GCC in nasal superior, temporal superior and temporal inferior 9 mm from macula were found statistically significant decrease in keratoconus group (p<0,05). In optic disc analysis fifth and the eleventh clock-hour quadrants of peripapiller retina nerve fiber layer and cup area ratio were found statistically significant decrease in keratoconic eyes (p<0,05). CONCLUSION: We thought that structural retinal changes seem in keratoconus eyes; keratoconus pathogenesis may affect not only cornea but also retina and optic nerve head.en_US
dc.identifier.doi10.4103/1319-4534.322604
dc.identifier.endpage260en_US
dc.identifier.issn1319-4534
dc.identifier.issn2542-6680
dc.identifier.issue4en_US
dc.identifier.pmid34527868en_US
dc.identifier.scopus2-s2.0-85111989328en_US
dc.identifier.scopusqualityQ3en_US
dc.identifier.startpage256en_US
dc.identifier.urihttps://doi.org/10.4103/1319-4534.322604
dc.identifier.urihttps://hdl.handle.net/11616/100105
dc.identifier.volume34en_US
dc.identifier.wosWOS:000680292900005en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherWolters Kluwer Medknow Publicationsen_US
dc.relation.ispartofSaudi Journal of Ophthalmologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectKeratoconusen_US
dc.subjectOptic coherence tomographyen_US
dc.subjectGanglion cell complexen_US
dc.subjectMacular thicknessen_US
dc.subjectRetinal nerve fiber layeren_US
dc.titleAssessment of ganglion cell complex, macular thickness, and optic disc parameters in keratoconus patientsen_US
dc.typeArticleen_US

Dosyalar