Mechanical analysis of 3D printed dental restorations manufactured using different resins and validation with FEM analysis

dc.contributor.authorGul, Buse Cebi
dc.contributor.authorDemirci, Fatih
dc.contributor.authorBaki, Nagehan
dc.contributor.authorBahce, Erkan
dc.contributor.authorOzcan, Mutlu
dc.date.accessioned2026-04-04T13:33:08Z
dc.date.available2026-04-04T13:33:08Z
dc.date.issued2025
dc.departmentİnönü Üniversitesi
dc.description.abstractPurpose The aim of this study was to compare the wear and fracture resistance of single crowns produced from newly developed 3D printer resins used to produce permanent crowns and currently used composite CAD/CAM discs, after being thermomechanically aged in a chewing simulator. Materials and methods A total of 112 stainless steel die models simulating mandibular left first molars were produced, 8 for each group. Single crowns were produced from 3 different discs (Grandio Voco [GR], breCAM HIPC [HC], and Shofu HC [SF]) by CAD/CAM milling method and manufactured from from 4 different permanent composite resins (Nexdent C&B MFH [ND], Permanent Bridge Saremco [PB], VarseoSmile Crownplus [VSC], and & Scedil;enertek P-Crown [PC]) using the 3D printing method. Stereomicroscopy, scanning electron microscope (SEM) and Finite Element Method (FEM) analysis was performed. Data were analyzed using ANOVA, paired-t tests and Tukey's HSD test (alpha = 0.05). Results As a result of thermomechanical aging, significant difference was found between the groups in wear and fracture resistance (P < .05). The highest wear resistance was found in the VSC group, and the lowest wear resistance in the PC group. As a result of the compression test, the highest fracture resistance was noted in the GR group and the lowest in the PC group. FEM analysis performed to validate fracture experiments showed an 87% similarity to the in-vitro data. Conclusions The crowns in all groups produced by CAD/CAM milling and 3D printing provided acceptable in vitro wear and fracture resistance for clinical application. The wear and fracture resistance of resin-based materials should be supported by clinical studies.
dc.description.sponsorshipInonu University Scientific Research Projects Unit, Malatya, Turkey [TDH-2023-3265]
dc.description.sponsorshipThis study was supported by grant No. TDH-2023-3265 from Inonu University Scientific Research Projects Unit, Malatya, Turkey.
dc.identifier.doi10.1186/s12903-024-05384-2
dc.identifier.issn1472-6831
dc.identifier.issue1
dc.identifier.orcid0000-0002-8744-5592
dc.identifier.orcid0000-0003-2634-3565
dc.identifier.orcid0000-0001-5389-5571
dc.identifier.pmid39856698
dc.identifier.scopus2-s2.0-85216999630
dc.identifier.scopusqualityQ2
dc.identifier.urihttps://doi.org/10.1186/s12903-024-05384-2
dc.identifier.urihttps://hdl.handle.net/11616/108958
dc.identifier.volume25
dc.identifier.wosWOS:001406375500006
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherBmc
dc.relation.ispartofBmc Oral Health
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20250329
dc.subjectAdditive manufacturing
dc.subjectCAD-CAM
dc.subjectChewing simulation
dc.subjectCrown
dc.subjectDental materials
dc.subjectMilling
dc.subjectProsthodontics
dc.subjectResin
dc.titleMechanical analysis of 3D printed dental restorations manufactured using different resins and validation with FEM analysis
dc.typeArticle

Dosyalar