Objective measurement of refractive errors Comparison of plusoptix s08 with a standard autorefractometer

dc.authorid9217en_US
dc.contributor.authorDemirel, Soner
dc.contributor.authorBilaki, Şemsettin
dc.contributor.authorYuvacı, İ.
dc.contributor.authorCumurcu, Tongabay
dc.contributor.authorÇolak, Cemil
dc.date.accessioned2017-08-18T12:03:44Z
dc.date.available2017-08-18T12:03:44Z
dc.date.issued2013
dc.departmentİnönü Üniversitesien_US
dc.description.abstractObjective: Comparison of Plusoptix S08 with a standart autorefractometer (Topcon RM 8000B) in children and adults. Methods: 220 eyes of 110 children, with a mean age of 8.06 ± 2.89 years old were examined to compare noncycloplegic measurements provided by Plusoptix S08 and cycloplegic measurements provided by Topcon RM- 8000B autorefractometer. In addition, 254 eyes of 127 adults, with a mean age of 33.3 ± 13.36 years old were examined to compare non-cycloplegic refractive measurements provided by Plusoptix S08 and Topcon RM 8000B autorefractometer. All measurements were repeated three times. Median sphere, cylinder, spherical equivalent and cylindrical axes as Jackson cross cylinder power measurements (J0 and J45) were compared statistically. Results: The median differences in spheres, cylinders, spherical equivalents, J0 and J45 powers were –0.25 D (P< 0.001), –0.25 D (P< 0.001), –0.25 D (P< 0.001), –0.02 (P= 0.038), 0.00 (P= 0.395), in children, respectively. These values were 0.50 (P<0.001), 0.00 (P<0.001), 0.375 (P<0.001), 0.03 (P= 0.053), 0.79 (P= 0.081), in adults, respectively. Conclusion: Plusoptix S08 has a myopic misspelled according to Topcon-RM8000B autorefractometer in children. However, measurements provided with Plusoptix S08 were more hyperopic than those with Topcon RM- 8000B autorefractometer in adults.en_US
dc.description.abstractAmaç: Çocuklarda ve erişkinlerdeki refraksiyon kusuru ölçümünde, Plusoptix S08 ile standart bir oto refraktometre (Topcon RM 8000B) ölçümlerinin karşılaştırılması. Yöntemler: Yaş ortalaması 8.06 ± 2.89 yıl olan 110 çocu- ğun 220 gözü Plusoptix S08 ile sikloplejisiz olarak, Topcon RM-8000B otorefraktometresiyle sikloplejili olarak ölçüldü. Elde edilen değerler karşılaştırıldı. Ayrıca, yaş ortalaması 33,3 ± 13,4 olan 127 yetişkinin 254 gözü, Plusoptix S08 ve Topcon RM 8000B otorefraktometre ile sikloplejisiz olarak ölçülerek, bu ölçümlerin karşılaştırması yapıldı. Tüm ölçümler üç kez tekrarlandı. Ortalama sferik, silindirik, sferik ekivalan ve silindirik aks değerleri istatistiksel olarak karşılaştırıldı. Bulgular: Ortalama sferik, silindirik, sferik ekivalan, J0 ve J45 güçleri çocuklarda sırasıyla: –0.25 D (p< 0.001), –0.25 D (p< 0.001), –0.25 D (p< 0.001), –0.02 (p= 0.038), 0.00 (p= 0.395) bulundu. Erişkinlerde ise 0.50 (p<0.001), 0.00 (p<0.001), 0.375 (p<0.001), 0.03 (p= 0.053), 0.79 (p= 0.081) olarak ölçüldü. Sonuç: Topcon-RM8000B otorefraktometreye göre Plusoptix S08 çocuklarda daha miyopik bir ölçüm yapmaktaydı. Ancak yetişkinlerdeki Plusoptix S08 ölçümleri daha hipermetropik izlenmekteydi.en_US
dc.identifier.citationDemirel, S. Bilaki, Ş. Yuvacı, İ. Cumurcu, T. Çolak, C. (2013). Objective measurement of refractive errors Comparison of plusoptix s08 with a standard autorefractometer. Journal of Clinical and Experimental Investigations. 4(1), 40–46.en_US
dc.identifier.doi10.5799/ahinjs.01.2013.01.0231en_US
dc.identifier.endpage46en_US
dc.identifier.issn1309-8578
dc.identifier.issn1309-6621
dc.identifier.issue1en_US
dc.identifier.startpage40en_US
dc.identifier.trdizinid151775en_US
dc.identifier.urihttps://doi.org/10.5799/ahinjs.01.2013.01.0231
dc.identifier.urihttps://hdl.handle.net/11616/7631
dc.identifier.urihttps://search.trdizin.gov.tr/yayin/detay/151775
dc.identifier.volume4en_US
dc.indekslendigikaynakTR-Dizinen_US
dc.language.isoenen_US
dc.publisherJournal of Clinical and Experimental Investigationsen_US
dc.relation.ispartofJournal of Clinical and Experimental Investigationsen_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectRefractive errorsen_US
dc.subjectAutorefractionen_US
dc.subjectPhotorefractionen_US
dc.subjectPlusoptix S08en_US
dc.subjectRefraksiyon kusuruen_US
dc.subjectPlusoptix S08en_US
dc.subjectFotorefraksiyonen_US
dc.subjectOtorefraksiyonen_US
dc.titleObjective measurement of refractive errors Comparison of plusoptix s08 with a standard autorefractometeren_US
dc.title.alternativeObjektif refraksiyon kusuru ölçümü: Plusoptix s08 ile standart bir otorefraktometrenin karşılaştırılmasıen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Makale Dosyası.pdf
Boyut:
1.18 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale Dosyası
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.71 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: