APPLICATION OF DIFFERENTIAL TRANSFORMATION METHOD FOR AN ANNULAR FIN WITH VARIABLE THERMAL CONDUCTIVITY
Küçük Resim Yok
Tarih
2022
Yazarlar
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Vinca Inst Nuclear Sci
Erişim Hakkı
info:eu-repo/semantics/openAccess
Özet
The thermal analysis of the annular fin is performed by applying the differential transformation method. The thermal conductivity of the annular fin has been considered as a function of temperature. The effects of non-dimensional parameters, namely thermal conductivity and thereto geometric fin parameters on the fin efficiency and temperature distribution are determined. Obtained results from the differential transformation method are also compared with the exact analytical results and the results of the finite difference method in the constant thermal conductivity condition. It has been concluded that the differential transformation method provides accurate results in the solution of non-linear problems.